S.I. No. 501/2010 - Taxes Consolidation Act 1997 (Accelerated Capital Allowances for Energy Efficient Equipment) (Amendment) (No. 3) Order 2010.


Notice of the making of this Statutory Instrument was published in

“Iris Oifigiúil” of 22nd October, 2010.

I, EAMON RYAN, Minister for Communications, Energy and Natural Resources, in exercise of the powers conferred on me by section 285A (inserted by section 46 of the Finance Act 2008 (No. 3 of 2008)) of the Taxes Consolidation Act 1997 (No. 39 of 1997), with the approval of, and after consultation with, the Minister for Finance, hereby order as follows:

1. (1) This Order may be cited as the Taxes Consolidation Act 1997 (Accelerated Capital Allowances for Energy Efficient Equipment) (Amendment) (No. 3) Order 2010.

(2) The collective citation, “the Taxes Consolidation Act 1997 (Accelerated Capital Allowances for Energy Efficient Equipment) Orders 2008, 2009 and 2010”, includes this Order.

2. In this Order “Principal Order” means the Taxes Consolidation Act 1997 (Accelerated Capital Allowances for Energy Efficient Equipment) Order 2008 ( S.I. No. 399 of 2008 ).

3. Schedule 1 of the Principal Order is amended by substituting the following for Part 1 of that Schedule:

“Part 1

Category: Motors and Drives

Technology: AC Induction Motors

An AC Induction Motor is an asynchronous electric motor that meets high efficiency standards. High efficiency AC induction motors are typically designed and constructed in such a manner as to reduce load losses (copper losses, rotor and stray load losses) and standing losses which are independent of the load (iron core and windage & friction losses). They can be considered either as standalone motors or as part of other equipment.

Eligibility criteria

In order to be included on the ACA Specified List, an AC induction motor must meet all of the requirements set out below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1.

Be a totally enclosed 3-phase induction motor with a power rating of greater than or equal to 1.1 kW.

2.

Meet the efficiency requirements listed on Table 1. according to IEC 60034-2-1 “Rotating Electrical machines — Standard methods for determining losses and efficiency of rotating electrical machinery from tests”, or scientific equivalent.

3.

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

4.

Appropriate operating and maintenance manuals must be available to the end-user in order to optimise the achievement of any potential energy efficiency gains.

Table 1 — Minimum Efficiency Criteria for Motors:

Power (kW)

2 PoleEfficiency % at Full load (50Hz)

4 PoleEfficiency % at Full load (50Hz)

6 PoleEfficiency % at Full load (50Hz)

1. 1

82. 7

84. 1

81. 0

1. 5

84. 2

85. 3

82. 5

2. 2

85. 9

86. 7

84. 3

3

87. 1

87. 7

85. 6

4

88. 1

88. 6

86. 8

5. 5

98. 2

89. 6

88. 0

7. 5

90. 1

90. 4

89. 1

11

91. 2

91. 4

90. 3

15

91. 9

92. 1

91. 2

18. 5

92. 4

92. 6

91. 7

22

92. 7

93. 0

92. 2

30

93. 3

93. 6

92. 9

37

93. 7

93. 9

93. 3

45

94. 0

94. 2

93. 7

55

94. 3

94. 6

94. 1

75

94. 7

95. 0

94. 6

90

95. 0

95. 2

94. 9

110

95. 2

95. 4

95. 1

132

95. 4

95. 6

95. 4

160

95. 6

95. 8

95. 6

200

95. 8

96. 0

95. 8

375

95. 8

96. 0

95. 8

>=400

96. 0

96. 0

96. 0

Notes:

1. Minimum efficiencies for 2-, 4- and 6-pole motors in the range 1.1kW to 375kW correspond to those for the IE3 premium efficiency class defined by the IEC 60034-30 standard.

2. For motors with more than 6 poles, the minimum efficiency criteria for 6-pole motors above shall apply.

3. Motors must be tested in accordance with IEC 60034-2-1 or scientific equivalent, where additional load losses are determined using low uncertainty methods.

4. Where a particular motor size is not listed, the required minimum efficiency level for the next size up must be met.

Testing for motors rated 400 kW and above must be certified by a body qualified and approved to test to IEC 60034-2-1 standard or equivalent. Detailed test results must be submitted and these results must be to the reasonable satisfaction of the Sustainable Energy Authority of Ireland”.

4. Schedule 1 of the Principal Order is amended by substituting the following for Part 3 of that Schedule:

“Part 3

Category: Lighting

Technology: Lighting Units

Lighting units are products that are specifically designed to provide efficient interior or exterior illumination.

Lighting units are considered to include:

High efficiency luminaires:

High efficiency Luminaires consist of a light fitting, one or more lamps and associated electronic control gear*.

Light emitting diode (LED) luminaires

LED Luminaires are solid state lighting devices consisting of a light fitting, one or more LED light sources, optical system and associated LED driver.

Light emitting diode (LED) lamps:

LED Lamps are solid state lighting devices consisting of a lamp with LED’s, integrated LED driver and lamp base suitable for existing light fittings.

*For High intensity discharge lamps (e.g. High-pressure sodium or metal halide) of individual lamp wattage greater than or equal to 200W suitable electronic control gear is not available and is therefore not a requirement.

Eligibility Criteria

In order to be included on the ACA Specified List, Lighting units must meet the relevant requirement set out below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General eligibility criteria

(applicable to all Lighting units)

No.

Condition

1.

All equipment and/or components must be CE marked as required by the specific EU directive(s).

2.

Must have a minimum power factor of 0.7 at all levels of product light output

High Efficiency Luminaires — Specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

3.

The photometric data of the Luminaires must have been measured and tested in accordance with EN 13032-1&2 “Light and lighting — Measurement and presentation of photometric data of lamps and Luminaires”

4.

Must meet the minimum efficacy criteria required for high efficiency luminaires as outlined in Table 1

5.

All lamps and control gear must be ENEC marked or comply with the relevant performance standards.

LED lamps and luminaires — Specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

6.

The photometric data of the Luminaire or lamp must have been measured and tested in accordance with:EN 13032-1&2 “Light and lighting — Measurement and presentation of photometric data of lamps and Luminaires” or IES LM-79-08 “Electrical and photometric measurements of Solid-State lighting products”.

7.

Must have a light output (in lumens) not less than 90% of initial1 light output after 6,000 hours of continuous operation and which is tested according to:IEC/PAS 62612 “Self ballasted LED-Lamps for general lighting services — performance requirements” or IES LM-80-08 “Measuring Lumen maintenance of LED light sources”.

8.

Luminaires must meet the minimum efficacy criteria required for LED luminaires as outlined in Table 1. Lamps must meet the minimum efficacy criteria in table 2.

9.

A minimum lumen output of 150 lumens for the whole lamp or luminaire.

10.

A colour rendering index not less than Ra70.

11.

A rated Correlated Colour Temperature between 2500 and 6500K

Table 1 — Luminaires: Minimum efficacies table for high-efficiency and LED Luminaires

Luminare type

Minimum efficacy(l l/cW)

High-pressure sodium 200W per lamp

80

High-pressure sodium <200W per lamp

65

Metal halide

65

Linear Fluorescent*

55

Compact Fluorescent* 300mm**

55

Compact Fluorescent* < 300mm**

45

Induction

45

LED

45

*Linear and Compact Fluorescent luminaires must have High frequency control gear incorporated into the fitting

**300mm in longest dimension

ll/cW = Luminaire Lumens per circuit Watts

= Total Lumen Output x Light Output Ratio

Circuit Power Drawn

Where:

• Total lumen output (Lumens)= the total light output of all the lamps in the fitting (measured in Lumens),

• Light Output Ratio (LOR) = ULOR and DLOR values may be combined where the fitting is designed to provide direct and indirect lighting, otherwise only the LOR in the intended lighting direction may be used.

• Circuit Power Drawn (Watts) = the electrical power drawn by the whole luminaire from main circuit connection point to lamp, including losses in the control gear (ballast)2

Table 2 — Lamps: Minimum efficacies table for LED lamps

LED Lamp type

Minimum efficacy l/cW

Omni directional*

45

Directional*

45

*As defined under Energy Star.

l/cW = Lumens per circuit Watts

= total lumen output

circuit power drawn

Where:

• Total lumen output (Lumens)= the total light output of the lamp

• Circuit Power Drawn (Watts) = the electrical power drawn by the whole lamp, including losses in the LED driver”.

5. Schedule 1 of the Principal Order is amended by substituting the following for Part 4 of that Schedule:

“Part 4

Category: Lighting

Technology: Lighting Controls

Systems used to control lighting with the aim of optimising energy usage. These systems use timers, daylight sensing, occupancy sensing and/or traffic flow sensing to control switching and/or dimming of lighting within different zones.

Lighting controls are considered to include:

Time controllers

Automatically switch off lighting, or dim it down, at predetermined times

Daylight controllers and sensors

Monitor daylight availability, and automatically switch off lighting or dim it down to the level needed to sufficiently illuminate the area.

Occupancy controllers and sensors

Monitor occupancy or movement of personnel, and automatically switch off, or dim down, lighting when the area is unoccupied.

Traffic flow controllers and sensors

Monitor traffic flow density, and automatically switch off, or dim down, lighting when a predetermined low average traffic flow is reached.

Eligibility Criteria

In order to be included on the ACA Specified List, Lighting Control equipment must meet all of the relevant requirements set out below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General eligibility criteria

(applicable to all lighting control equipment)

No.

Condition

1.

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2.

Where automatic dimming controls are used, they must work by reducing the power consumption of the lamps. And,• Where LED lighting or fluorescent lighting is being dimmed, the controls must be capable of reducing the power consumption of the controlled lamps by at least 50%. • Where fluorescent lighting is being dimmed, it must incorporate high frequency control gear with dimmable ballasts. • Where other forms of lighting than fluorescent are being dimmed, they must incorporate either mains frequency or high frequency control gear with dimmable ballasts.

Time controllers — specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

3.

The product must automatically switch the lighting off, or dim it down, at predetermined times, or after a predefined interval.

Daylight controllers — specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

4.

The product must monitor the availability of daylight and automatically switch the lighting off when sufficient daylight is available to illuminate the area irrespective of switching cycle mode. Controls that incorporate dimming must dim down the lighting to the level needed to sufficiently illuminate the area by a combination of daylight and electric light.

Occupancy controllers — specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

5.

The product must automatically switch off the lighting, or dim it down, after the area has become unoccupied.

Traffic flow controllers — specific eligibility criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

4.

The product must automatically switch the lighting off, or dim it down, when a predetermined low average traffic flow is reached.

Notes

1. Modules which can be added to a lighting control system/product but do not control or monitor lighting are not eligible for ACA support as lighting controls.

2. Products may incorporate the facility for local users to manually switch on and off lighting in a local area and thus to override the relevant lighting controls at any particular instance. However products that allow local users to locally override the ability of lighting controls to automatically switch off or dim down the lighting, are not eligible”.

6. Schedule 1 of the Principal Order is amended by substituting the following for Part 23 of that Schedule:

“Part 23

Category: Process and Heating, Ventilation and Air-conditioning (HVAC) Control Systems

Technology: Heat Exchangers

Heat Exchangers are equipment that is specifically designed to enable the efficient transfer of energy from one liquid or gas stream to another, in both heating and cooling applications.

Heat Exchanger equipment is considered to include the following:

Run-around Coil heat exchangers

A Run-around Coil heat exchanger transfers energy from an exhaust air stream to a supply air stream via an energy transfer medium circuit (usually water) connecting the two energy streams.

Liquid-to-liquid Plate heat exchangers

Liquid-to-liquid plate heat exchangers comprise of a series of formed plates through which liquid streams are channeled in alternate flows. Energy is transferred between an exhaust and supply liquid stream via the exchangers and an energy transfer circuit.

Air-to-air Plate heat exchangers

Air-to-air plate heat exchangers comprise of a series of formed plates through which air streams are channeled in alternate flows. Energy is transferred between an exhaust and supply airstream via the exchangers and an energy transfer circuit.

Thermal Wheel heat exchangers

Thermal wheel heat exchangers are installed where the exhaust air stream is directly adjacent to the supply air stream. The wheel rotates slowly on an axis perpendicular to air flow. The rotation of the wheel transfers energy between the two streams.

Eligibility Criteria

In order to be included on the ACA Specified List, the specific heat exchanger equipment must satisfy all of the relevant requirements set out below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Heat Exchanger Eligibility Criteria

(Applicable to all heat exchanger equipment)

No.

Condition

1.

All equipment and/or components must be CE marked as required by the specific EU directive(s).

2.

All required performance values must be tested according to:• EN305 “Heat exchangers. Definitions of performance of heat exchangers and the general test procedure for establishing performance of all heat exchangers”• EN 306 “Heat exchangers. Methods of measuring the parameters necessary for establishing the performance”• EN 308 “Heat exchangers — Test procedures for establishing the performance of air to air and flue gases heat recovery devices” As specified for each individual condition,or scientific equivalent.

Run-around heat exchangers — specific Eligibility Criteria

(To be met in addition to the general eligibility criteria)

No.

Condition

3.

A heat transfer efficiency greater than or equal to 50% during maximum capacity operation tested in compliance with EN305/EN306.

4.

A maximum air side pressure drop across an individual heat exchanger coil of 100 Pa. tested in compliance with EN305/EN306.

5.

A maximum water side pressure drop across an individual heat exchanger coil of 25 kPa tested in compliance with EN305/EN306.

Liquid-to-liquid Plate Heat exchangers — specific Eligibility Criteria

(To be met in addition to the general eligibility criteria)

6.

A ratio of internal heat exchanging surface area to maximum operating volume greater than 200. (m2/m3 >200). tested in compliance with EN305/EN306.

7.

A heat transfer efficiency greater than or equal to 85% during maximum capacity operation. tested in compliance with EN305/EN306.

Air-to-air Plate Heat exchangers — specific Eligibility Criteria

(To be met in addition to the general eligibility criteria)

No.

Condition

8.

A heat transfer efficiency greater than or equal to 50% during maximum capacity operation. tested in compliance with EN308.

9.

A maximum pressure drop across the heat exchanger of 250 Pa tested in compliance with EN308.

Thermal Wheel heat exchangers — specific Eligibility Criteria

(To be met in addition to the general eligibility criteria)

No.

Condition

10.

A heat transfer efficiency greater than or equal to 70% during maximum capacity operation tested in compliance with EN308.

11.

A maximum pressure drop across the heat exchanger component of 200 Pa. tested in compliance with EN308.

”.

7. Schedule 1 of the Principal Order is amended by inserting the following:

“Part 30

Category: Refrigeration and Cooling

Technology: Compressors and Condensing Units

Compressors and Condensing Units are defined as equipment designed to compress refrigerant vapour, and in the case of Condensing Units to also condense that vapour into a liquid, achieving very high operational efficiencies.

Compressors and Condensing Units equipment is considered to include the following:

Compressors

Refrigeration compressors are products specifically designed to raise the pressure, temperature and energy level of a refrigerant vapour by mechanical means, as part of a vapour-compression, economised vapour-compression or transcritical CO2 refrigeration cycle.

Economiser packages consist of a refrigeration compressor, an expansion device, and an economiser that is capable of increasing refrigerant sub-cooling and refrigeration cycle efficiency.

Condensing Units

Air-Cooled Condensing Units products are specifically designed to provide cooling to other equipment and systems that incorporate evaporators (and associated expansion valve control systems). Air-cooled condensing units are factory-assembled units that consist of one or more compressors, an air-cooled condenser and interconnecting pipework. They may include liquid receivers, filter driers, oil separators, shut-off valves and related controls, and a weatherproof housing.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Refrigeration and Cooling equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Refrigeration and Condensing Units)

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s)

2

Be designed to operate with one or more clearly identified standard refrigerants

3

Compressors must be hermetic or semi-hermetic type. Products that depend on an external motor for compressor operation (i.e. ‘open’-type compressors) are not eligible

Compressors — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

4

Be either a refrigeration compressor or an economiser package

5

Incorporate a positive displacement type, hermetic or semi-hermetic compressor (with integral electric motor)

6

Have a displacement greater than 9 cubic metres per hour, except for products using R744 which must have a displacement greater than 5 cubic metres per hour

7

Products must have a coefficient of performance (COP) that is greater than the values shown in Table 1 (below) at the specified rating points. COP must be calculated according to IS EN 12900:2005 ‘Refrigerant compressors — Rating conditions, tolerances and presentation of manufacturer’s performance data’.

8

Low-temperature transcritical/subcritical R744 products must include an appropriately matched gas intercooler that is capable of reducing the intermediate gas temperature to the level required for second-stage compression

Condensing Units — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

9

Be a factory-assembled unit that incorporates at least the following components: a) Air-cooled refrigerant condenser b) One or more electrically driven refrigeration compressors c) A control system that controls the product’s compressors and cooling fan(s)

10

Fall into one or more of the following three temperature categories: • High-temperature units Medium-temperature units Low-temperature units

11

Products must have a coefficient of performance (COP) that is greater than the values shown in Table 2 (below) at the specified rating points

Table 1: Minimum performance thresholds for refrigeration compressors at the Republic of Ireland (RoI) rating points

Category

Evaporating temperature (dew point)

Condensing temperature (dew point)

Compressor suction gas temperature

Liquid sub-cooling

COP threshold

High-temperature with HFC3 or HC4 refrigerant

+5°C

35°C

20°C

0K

> 5.20

Medium-temperature with HFC or HC refrigerant

-10°C

30°C

20°C

0K

> 3.36

Low-temperature with HFC or HC refrigerant

-35°C

25°C

20°C

0K

> 1.94

Medium-temperature transcritical/ subcritical with R744 refrigerant

-10°C

15°C

0°C

0K

> 4.20

Low-temperature transcritical/ subcritical with R744 refrigerant

-35°C

15°C

-25°C

0K

> 1.80

Low-temperature subcritical with R744

-35°C

-5°C

-25°C

0K

> 3.20

Note: For economiser packages, zero subcooling refers to the liquid condition at the condenser exit.

Table 2: Performance thresholds for air-cooled condensing units at the RoI rating points

Temperature category

Evaporating temperature (dew point)

Ambient (condenser air-on) temperature

Compressor suction gas temperature

COP threshold

High-temperature units

+5°C

20°C

20°C

3.9

Medium-temperature units

-10°C

20°C

20°C

2.8

Low-temperature units

-35°C

20°C

20°C

1.6

Where:

COP = refrigerating capacity/power absorbed, including the compressor and the condenser fans (and any other power use associated with the air-cooled condensing unit)

The refrigerating capacity and power absorbed are as defined in IS EN 13215:2000 — ‘Condensing units for refrigeration — Rating conditions, tolerances and presentation of manufacturer’s performance data’, and the power absorbed must be measured at full load, without condenser pressure control, and must include the fan power.

Part 31

Category: Refrigeration and Cooling Systems

Technology: Refrigerated Display Cabinet equipment

Refrigerated Display Cabinet equipment is defined as equipment that is designed to store and display chilled and/or frozen foodstuffs.

Refrigerated Display Cabinet equipment is considered to include the following:

Refrigerated Display Cabinets

Refrigerated display cabinets are used to maintain foodstuffs and drinks at chilled and frozen temperatures. There are many different designs of refrigerated display cabinets, but all enable the customer to view the foodstuff stored in the cabinet, either through an opening in the cabinet, or through a transparent door or lid. The two types of cabinets included are:

• ‘Plug-in’ refrigerated display cabinets with integral refrigeration systems (i.e. incorporating a compressor and condensing unit)

• ‘Remote’ refrigerated display cabinets that are designed to work with a non-integral refrigeration system (i.e. where the compressor and condenser, or all or parts of the refrigeration system, are located at a different location from the cabinet)

Covers for Refrigerated Display Cabinets

Covers for Refrigerated Display Cabinets are rigid barriers that can be used to reduce the infiltration of ambient air and heat flow into refrigerated display cabinets, thereby reducing the energy consumption of the cabinet. The five types of covers included are:

1. Strip curtains that consist of transparent, flexible strips hung adjacent to each other, and fastened at both ends to neighbouring strips, in a manner that allows temporary openings to be made in the curtain for the purpose of removing items from the cabinet.

2. Night blinds that consist of a flexible fabric mounted on a roller mechanism that enables the blind to be deployed across the display window of the cabinet when the retail outlet is closed. The blind may also incorporate a motorised control system.

3. Transparent chest freezer covers (or ‘bubble lids’) that consist of a rigid transparent material that fits across the display window of the cabinet, and incorporates access holes that enable items to be removed from the cabinet without removing the cover.

4. Transparent sliding doors that consist of doors with a heat-reflective coating, mounted in a mechanism (designed to be installed in the window of the cabinet) that enables the doors to be opened when items need to be removed from the cabinet.

5. Transparent hinged doors that consist of doors with a heat-reflective coating, mounted in a mechanism (designed to be installed in the window of the cabinet) that enables the doors to be opened when items need to be removed from the cabinet.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Refrigerated Display Cabinet equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Refrigerated Display Cabinet equipment)

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

Refrigerated Display Cabinets — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

2

Be designed to display chilled and/or frozen foodstuffs, while maintaining them within prescribed temperature limits

3

Conform to one of the temperature classifications in Table 1 (see below) when tested to IS EN ISO 23953-2:2005 in climate class III (25°C, 60% RH)

4

Have an Energy Efficiency Index (EEI) that is less than, or equal to, the threshold shown in Table 2 (see below) for the relevant temperature class and type of cabinet

5

Be classified in accordance with the precise 5-digit classification system set out in Annex A of IS EN ISO 23953-1:2005

Covers for Refrigerated Display Cabinets — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

6

Products must: • Provide a rigid barrier that can be used to reduce the infiltration of ambient air and heat flow through the open display window of a refrigerated display cabine• Be designed to fit one or more specific types or models of refrigerated display cabinet in a manner that ensures that, when fitted, there is no air gap around the edges of the product’s rigid barriers

Table 1: Classification according to temperature

Class

Highest temperature ah of warmest M-package equal to or lower than:

Lowest temperature b of coldest M-package equal to or higher than:

Lowest temperature al of warmest M-package equal to or lower than:

L1

-15°C

-

-18°C

L3

-12°C

-

-15°C

M0*

+4°C

-1°C

-

M1

+5°C

-1°C

-

M2

+7°C

-1°C

-

H1

+10°C

+1°C

-

H2

+10°C

-1°C

-

*Note: All classes are as described in IS EN ISO 23953-2:2005, except M0, which is based on recommendations by the British Refrigeration Association.

Table 2: Performance thresholds for refrigerated display cabinets

Classification according to temperature

EEI performance threshold(kWh/day/m2)

Integral type

Remote type

L1

21. 00

23. 50

L3

n/a

21. 00

M0

12. 50

11. 75

M1

12. 20

11. 45

M2

11. 60

10. 85

H1

n/a

8. 00

H2

10. 20

9. 20

Where the Energy Efficiency Index (EEI) is defined as the ratio of the product’s Total Energy Consumption (TEC) to Total Display Area (TDA), i.e. EEI = TEC/TDA, and:

TEC is calculated according to IS EN ISO 23953-2:2005 section 5.3.6.3.4

TDA is calculated according to IS EN ISO 23953-2:2005 Annex A

Part 32

Category: Refrigeration and Cooling

Technology: Condensers

Condensers are defined as equipment that is designed to cool and condense high-pressure refrigerant vapour by means of a heat exchanger.

Condenser equipment is considered to include the following:

Evaporative Condensers

Evaporative Condensers are specifically designed to cool and condense high-pressure refrigerant vapour by means of a heat exchanger that has a continuously wetted external surface across which air is blown by a fan.

Air-Cooled Condensers

Air-cooled Condensers are specifically designed to cool and condense high-pressure refrigerant vapour by means of a heat exchanger across which air is blown by a fan.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Condenser equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Condenser equipment)

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

Products must incorporate: • A heat exchanger that is designed to cool and condense refrigerant vapour • A fan that blows air over the heat exchanger

Evaporative Condensers — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

3

Products must incorporate a mechanism that continually wets the external surface of the heat exchanger, and that includes a water pump and a water storage tank

4

Equipment must be manufactured so as to comply fully with all applicable requirements of the ‘National Guidelines for the Control of Legionellosis in Ireland 2009’ (or later edition)

Air-Cooled Condensers — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

5

Meet the performance criteria measured by the Energy Efficiency Ratio (EER) of the unit at 100% (full) load capacity, as indicated in Table 1

Table 1: Minimum Energy Efficiency Ratio (EER) performance values

Type

EER

Air-Cooled Condenser

110

Where: EER = Net heat rejection capacity kW (@T 15K)

Absorbed electrical power kW

Part 33

Category: Refrigeration and Cooling Systems

Technology: Refrigeration System Controls

Refrigeration System Controls are defined as equipment that controls and optimises the temperatures and pressures in a refrigeration system, and automatically adjusts the refrigeration system’s operation to minimise its energy consumption, while maintaining within predefined temperature limits the spaces, processes or equipment being refrigerated, and reflecting changes in load, weather conditions and operating requirements.

Refrigeration System Controls equipment is considered to include the following:

System Management Package

This consists of one or more control units or modules designed to optimise an entire refrigeration system, including the operation of refrigeration compressor(s), evaporator(s) and condenser(s).

‘Add-on’ Controllers

These are designed to be used in conjunction with a specific system management unit or package, and enable the operation of additional refrigeration compressors, evaporators and condensers to be optimised

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Refrigeration System Controls equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Refrigeration System Controls equipment)

No.

Condition

1.

All equipment and/or components must be CE marked as required by the specific EU directive(s).

2.

Must comply with the relevant requirements, as set out in Tables 1 to 3 below, for products that directly control by means of an analogue or digital signal connection: a) Evaporators (see Table 1) b) Condensers (see Table 2) c) Compressors (see Table 3)

3.

Products must incorporate a microprocessor-based controller that is pre-programmed to automatically control the rate of flow of refrigerant through, and/or operating temperature of, at least one of the following types of refrigeration equipment: a) Evaporatorsb) Condensers c) Compressors

System Management Package — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

4.

Must automatically adjust the system operating set points in a manner that minimises the refrigeration system’s energy consumption under different operating loads, weather conditions and surrounding air temperatures

5.

Is pre-programmed to undertake one or more of the following: i. Monitor temperatures and/or pressures around the refrigeration system, and automatically initiate defrost cycles, or inhibit (or delay) scheduled defrost cycles, within individual parts of the refrigeration system, as required, to optimise the overall performance of the refrigeration system ii. Monitor refrigeration system energy input (kWh) and generate a visual or audible alarm when system power consumption exceeds a pre-defined limit, or when system efficiency degradation is preventing automatic adjustment iii. Automatically, in accordance with a pre-defined weekly time schedule, turn off, or turn down, ancillary power loads around the refrigeration system (such as lighting in display cabinets, trim heaters or fans), or activate night blinds, in order to reduce system energy consumption

6.

Must provide facilities that enable system managers to define the default set points, and alarm limits, for each item of refrigeration equipment controlled.

‘Add-on’ Controller — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

7.

Must automatically accept instructions from the system manager to change its operating set points or alarm limits, or to initiate or inhibit a defrost cycle.

8.

Must automatically transmit data on operating temperatures, pressures, or flow rates to the system manager at intervals not exceeding 10 minutes.

Table 1: Control of evaporators

All products that directly control evaporators must:

No.

Requirement

a.

Be designed to directly measure evaporator pressure or temperature by means of a sensor, and automatically adjust the flow of refrigerant through the evaporator to maintain the refrigerated space within pre-defined operating limits.

b.

Automatically terminate its defrost cycle when: • The temperature of the evaporator or refrigerated space exceeds a preset value.• A maximum defrost time consistent with sensor failure has been exceeded.

c.

Provide facilities that enable system managers to define separate temperature set points and alarm limits for each evaporator being controlled.

d.

Provide facilities that enable system managers to take the equipment out of service for cleaning or maintenance.

e.

Generate an alarm signal when the temperature of the refrigerated space is in danger of straying outside, or has strayed outside, its pre-defined safe operating limits.

Table 2: Control of condensers

All products that directly control condensers must:

No.

Requirement

a.

Be designed to directly measure condenser pressure or temperature by means of a sensor, and automatically adjust the airflow across the condenser(s) in a manner that maintains condensation at the rate required to maintain the thermal balance of the refrigeration system under different operating loads and weather conditions.

b.

Allow the compressor discharge (head) pressure to ‘float’ with ambient temperature down to the minimum safe level for the particular refrigeration system for maximum system efficiency.

c.

Provide facilities that enable system managers to define separate temperature set points and alarm limits for each condenser being controlled.

d.

Generate an alarm signal when the condensing pressure or temperature is in danger of straying outside, or has strayed outside, the predefined limits for safety or efficiency.

Table 3: Control of compressors

All products that directly control compressors must:

No.

Requirement

a.

Be able to control the operation of at least two refrigeration compressors.

b.

Incorporate automatic control algorithms that monitor rate of change in system suction pressure or refrigerant temperature to prevent compressors from unnecessarily being controlled to load or unload in response to small fluctuations in cooling demand.

Where:

• Automatic control may be implemented either directly by means of an analogue or digital signal connection, or indirectly by means of another control device or network.

• A mechanism is defined as “any sequence of pre-defined actions that performs a given function, where an action can be defined in hardware and/or software”.

• An algorithm is defined as “a mechanism that is defined in software”.

• The product’s control strategy is the combination of automatic control functions, mechanisms and facilities specified for the particular equipment controlled. In this context, products may be pre-programmed in one of the following ways:

a) One or more fixed control strategies that are designed to control a specific set of equipment that can be selected during commissioning

b) One or more flexible control strategies that can be configured to control different equipment, as part of a clearly defined commissioning procedure

Part 34

Category: Electro-Mechanical Systems

Technology: Injection Blow Moulding Machines

An Injection Blow Moulding Machine (IBMM) is a machine for the injection blow moulding of thermoplastics that:

Melts and plasticizes the thermoplastic raw material

Closes the mould and clamps closed the pre-form mould

Injects the plasticized raw material into the pre-form mould and holds it under pressure until it has solidified

Opens the pre-form mould and rotates or otherwise moves the pre-form to the blowing station

Closes the blowing station mould over the pre-form

Injects high-pressure compressed air into the hot pre-form to expand the pre-form to the final shape

Ejects the completed product

IBMMs have traditionally been powered by hydraulic systems using a hydraulic pump and hydraulic motors. The newer generation of IBMMs use electrical servo-motors to provide variable power to the machine; these are called ‘all-electric machines’.

Eligibility Criteria Overview

To be included on the ACA Specified List, an Injection Blow Moulding Machine (IBMM) must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

The IBMM drive system is to be primarily servo-motor-controlled.Limited hydraulic motors are allowed for hybrid systems but hydraulic motor energy use is to be less than 40% of total IBMM energy use.

3

The average power consumption of the IBMM shall be less than:kW = 0.3 x (Production Rate) + 22where the ‘Production Rate’ is measured in kg/hour of machine throughput.

4

Appropriate operating & maintenance manuals must be available to the end-user in order to maximise the achievement of any potential energy-efficiency gains.

Notes:

1. Some manufacturers will use a ‘hybrid’ technology combining both electric and hydraulic operation for specific applications. This allows processors to benefit from the advantages of both electric and hydraulic operations. In these cases, the hydraulic element of the power consumption (kW) shall be less than 40% of the total power consumption of the IBMM.

2. In some existing tooling, hydraulic control of mould movements is needed and is currently powered from the IBMM’s hydraulic system. In these cases, a hydraulic power pack may be required to allow existing tooling to be used on all-electric machines. The power consumption use of any such hydraulic power pack is not included in the power consumption assessment of the machine.

3. Where the process is injection stretch blow moulding (ISBM), the same conditions for ACA eligibility shall apply.

Part 35

Category: Electro-Mechanical Systems

Technology: Injection Moulding Machines

An Injection Moulding Machine (IMM) is a machine for the injection moulding of thermoplastics that:

Melts and plasticizes the thermoplastic raw material

Closes the mould and clamps the mould closed

Injects the plasticized raw material into the mould and holds it under pressure until it has solidified

Opens the mould and ejects the completed product

IMMs have traditionally been powered by hydraulic systems using a hydraulic pump and hydraulic motors. The newer generation of IMMs uses electrical servo-motors to provide variable power to the machine; these are called ‘all-electric machines’.

Eligibility Criteria Overview

To be included on the ACA Specified List, an Injection Moulding Machine (IMM) must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

The IMM drive system is to be primarily servo-motor-controlled.Limited hydraulic motors are allowed for hybrid systems but hydraulic motor energy use is to be less than 40% of total IMM energy use.

3

The average power consumption of the IMM shall be less than:kW = 0.6 x (Production Rate) + 4where the ‘Production Rate’ is measured in kg/hour of machine throughput (product + any sprues and runners).

4

Appropriate operating and maintenance manuals must be available to the end-user in order to maximise the achievement of any potential energy-efficiency gains.

Notes:

1. Some manufacturers use a ‘hybrid’ technology combining both electric and hydraulic operation for specific applications. This allows processors to benefit from the advantages of both electric and hydraulic operations. In these cases, the hydraulic element of the power consumption (kW) shall be less than 40% of the total power consumption of the IMM.

2. In some existing tooling, hydraulic control of mould movements is needed and is currently powered from the IMM’s hydraulic system. In these cases a hydraulic power pack may be required to allow existing tooling to be used on all-electric machines. The power consumption use of any such hydraulic power pack is not included in the power consumption assessment of the machine.

Part 36

Category: Electro-Mechanical Systems

Technology: Extrusion Blow Moulding Machines

An Extrusion Blow Moulding Machine (EBMM) is a machine for the extrusion blow moulding of thermoplastics that:

Melts and plasticizes the thermoplastic raw material

Extrudes a hollow parison from the extrusion head

Closes the mould around the parison

Injects high-pressure compressed air into the parison, to expand it to the final shape

Trims the ‘tops and tails’ from the product

Opens the mould

Removes the completed product from the mould to the packing station

Recycles the ‘tops and tails’ back into the process via conveyors, regranulators and blowers

EBMMs have traditionally been powered by extruder motors with hydraulic systems for most of the machine movements. The newer generation of EBMMs uses electrical servo-motors to provide variable power for the machine movements. These are called ‘all-electric machines’.

Eligibility Criteria Overview

To be included on the ACA Specified List, an Extrusion Blow Moulding Machine (EBMM) must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

The EBMM machine movements are to be primarily servo-motor-controlled.Limited hydraulic motors are allowed for hybrid systems, but hydraulic motor energy use is to be less than 25% of total EBMM energy use.

3

The average power consumption of the entire EBMM shall be less than:kW = 0.22 x (Production Rate) + 18where the ‘Production Rate’ is measured in kg/hour of total machine throughput (product + any tops and tails).

4

Appropriate operating and maintenance manuals must be available to the end-user in order to maximise the achievement of potential energy efficiency gains.

Notes:

1. Some manufacturers will use a ‘hybrid’ technology combining both electric and hydraulic operation for specific machine movements. This allows processors to benefit from the advantages of both electric and hydraulic operations. In these cases, the hydraulic element of the power consumption (kW) shall be less than 25% of the total power consumption of the EBMM.

2. In some existing tooling, hydraulic control of mould movements may be needed, and s currently powered from the EBMM’s hydraulic system. In these cases, a hydraulic power pack may be required to allow existing tooling to be used on all-electric machines. The power consumption use of any such hydraulic power pack is not included in the power consumption assessment of the machine.

Part 37

Category: Electro-Mechanical Systems

Technology: Process Energy Management Systems

Process Energy Management Systems (PEMS) are hardware, firmware or software control systems designed to manage the energy consumption of energy-using equipment, with the sole aim of optimising energy efficiency within the process and meeting specified energy-efficiency standards.

Eligibility Criteria Overview

To be included on the ACA Specified List, a PEMS must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

Inputs to the system must include energy use and process/system conditions.

2

The system must provide a user interface that alerts the user when the system is not performing to its specified conditions.

3

The system must control the operation of more than one piece of standalone machinery, and the equipment must be able to operate without the PEMS (i.e. the system is not an integral part of the operating controls of a machine).

4

All controlled variables on the system must have upper and lower control limits and alert the user when these are outside of required bands, along with the energy impact expected.

5

The system shall have at least one key performance indicator that will be a good indicator of the energy efficiency of the operation of the process/equipment, with an ability to set both upper and lower bands of acceptance.

6

The system must allow the user to monitor and archive energy-related data, and have the capacity to generate standard interchange files that will allow other computer systems to use the data collected.

7

The device will have the functionality to cause controlled devices to be set to inactive mode after defined periods of inactivity.

8

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

9

Appropriate installation, operating and maintenance manuals, including an appropriate connections diagram, must be available for the end-user as part of the main contract of sale, along with any software supports required to communicate with external devices in order to maximise the achievement of any potential efficiency improvements when installed.

Part 38

Category: Electro-Mechanical Systems

Technology: Voltage Stabilisation

Voltage Stabilisation is defined as equipment designed to control the delivered output voltages within a specific acceptable range. It also provides for efficient use of electrical energy in electro-mechanical devices when the supply voltage variations fall outside of the specific acceptable range. Typical voltage stabilisation equipment includes voltage optimisers, voltage regulators and voltage stabilisers.

Eligibility Criteria Overview

To be included on the ACA Specified List, Voltage Stabilisation equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

The device must control the output voltage within a 1% range of set point when the supply voltage falls between the levels of 207V and 243.8V single-phase, or associated 3-phase voltages if a 3-phase unit.

2

Where the unit is three-phase, the unit must be capable of providing an equal three-phase output (balanced) in cases where the input supply voltages are not equal.

3

Insertion losses of the unit must not exceed an overall average of 1% over the ranges of 20%, 40%, 60%, 80% and 95% rated output load. The average shall be calculated as being the weighted average of each of the individual insertion losses in % terms. The defined connection profile is that the connected load will be 20% rated load for 10% of the time, 40% rated load for 20% of the time, 60% rated load for 30% of the time, 80% rated load for 30% of the time, and 95% rated load for 10% of the time.

4

The device must have a nominal output power rating of greater than or equal to 10kVA and less than or equal to 2MVA.

5

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

6

Documentation must be supplied with the unit that provides clear indications to the purchaser of expected savings in sample installation situations, outlining (a) the initial supply voltage, (b) the final controlled voltage and (c) the type of equipment connected. This will also include situations where savings are minimal or zero for (a) the case where existing supply voltages lead to minimal savings, and also separately for (b) the case where the supply voltages are high but significant amounts of installed equipment do not readily lend themselves to energy savings. The documentation shall provide a clear indication to the end-user of the types of equipment that do NOT typically provide savings when connected to these devices.

7

Appropriate installation, operating and maintenance manuals, including a wiring diagram, must be available for the end-user as part of the main contract of sale, along with any specific software or commissioning tools required in order to maximise the achievement of any potential efficiency improvements when installed.

Part 39

Category: Electro-Mechanical Systems

Technology: Electrical Actuators

An electrical actuator is a device that receives an electrical signal in the form of a controlled voltage, current or digital control signal from a device controller, and causes a mechanical part to move in a linear or rotational manner by a defined amount.

Actuators are considered to include multi-turn, partial turn or linear types which control valves, air dampers or similar devices.

Eligibility Criteria Overview

To be included on the ACA specified list, an electrical actuator must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

Actuator shall have a nominal input power rating of greater than or equal to 60W and less than or equal to 6kW.

3

Actuator electrical control signal shall cause the actuator to change state or position as desired, using electrical energy sources solely. Power supplies to provide the drive forces may be DC or single/ 3-phase AC only.

4

The actuator shall remain in its set position when external power is removed from the device and shall not consume energy from its main drive circuitry when in a fixed position and stationary for more than 10 seconds.

5

Appropriate installation, operating and maintenance manuals, including wiring diagram, must be available for the end-user as part of the main contract of sale, along with any specific actuator commissioning tools required in order to optimise potential efficiency improvements when installed.

Part 40

Category: Catering and Hospitality Equipment

Technology: Commercial Combination Ovens

Commercial electric and gas combination ovens are used in commercial kitchens and catering. They are categorised as electric (both full and half-size) and gas convection ovens (full-size only) where cookery within one unit is possible by using a combination of convection heat and steam.

Commercial Combination Ovens are considered to include the following:

Electric-Powered Combi Ovens

Electric-powered combi ovens are defined as half-size (capacity for a min. five pans5 ) and full-size (capacity for a min. 10 pans).

Gas Convection Ovens

Gas convection ovens are defined as full-size only (capacity for a min. ten pans).

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Commercial Combination Oven must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Commercial Combination Ovens)

No.

Condition

1

All equipment and/or components must be CE marked as required by the specific EU directive(s).

2

Must comply with the Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS)6 and Waste Electrical and Electronic Equipment (WEEE)7 regulations.

3

Must have the option to be supplied with an integrated condenser hood to regulate climate control in the location where it will operate or a heat exchanger to transfer heat from the steam exhaust to the incoming water.

Electric-Powered Combi Ovens — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

4

Must achieve a minimum cooking efficiency of 70% (both half and full-size units).

5

Must not exceed 1.6 kW (for full-size ovens) or 1.0 kW (for half-size ovens) in electrical energy consumption while operating at a stabilised temperature set point (standby rate)

Gas Convection Ovens — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

6

Must achieve a minimum cooking efficiency of 44%

7

Must not exceed 3.8 kWh gas consumption while operating at a stabilised temperature set point (standby rate)

Part 41

Category: Catering & Hospitality Equipment

Technology: Commercial Dishwashers

Commercial Dishwashers are defined as equipment constructed in stainless steel for use in commercial kitchens and to clean and sanitise dishes, plates, utensils, glasses, trays, cups, and bowls.

Commercial Dishwasher equipment is considered to include the following:

Undercounter Dishwashers

Undercounter dishwashers are loaded and unloaded by opening a drop-down door to the front of the machine and are typically less than 1000mm high. Maximum output per hour is 30 racks.

Stationary Single Tank Door Dishwashers

These include hood-type dishwashers and potwashers. They work by passing the racks through the stationary wash chamber. Maximum output per hour is 45 racks.

Single and Multiple Tank Rack Conveyor Dishwashers

Rack-type dishwashers feed baskets through the machine using a moving rack. Output ranges from 100 to 190 racks per hour.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Commercial Dishwasher must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Commercial Dishwashers)

No.

Condition

1

All equipment and/or components must be CE marked as required by the specific EU directive(s).

2

Must comply with the Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS)8 and Waste Electrical and Electronic Equipment (WEEE)9 regulations.

3

Must have a maximum water consumption as per Table 1 below

4

Must have a maximum idle energy rate as per Table 1 below (measured with door closed, representative of the energy used by the tank heater only)

Single and Multiple Tank Rack Conveyor Dishwasher — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

5

Must incorporate a heat-recovery system to preheat rinse water to a minimum temperature of 40° C

Table 1: Minimum Dishwasher Water Consumption and Idle Energy Rates

Dishwasher Type

Water Consumption(litres pre rack)

Idle Energy Rate(kW per hour)

Under-counter

3

0. 9

Stationary Single Tank Door

3

1

Single and Multiple Tank Rack Conveyor

2. 9

2. 6

Part 42

Category: Catering & Hospitality Equipment

Technology: Commercial Water Boilers

Commercial Water Boilers are defined as electrically powered equipment that delivers hot water (>90C) for use in the catering, restaurant and vending sectors. These units are automatically fed from, and thus continuously coupled to, the main potable water supply.

Eligibility Criteria Overview

To be included on the ACA Specified List, a Commercial Water Boiler must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

Must have a storage capacity of greater than or equal to 5 litres and less than or equal to 25 litres

3

Efficiency during a normal operating period must be >95%

4

Standby energy loss <100WStandby energy loss is calculated as the energy consumption of a filled water heater, after steady-state conditions have been reached when connected to electrical supply, when no water is drawn for 24 hours

5

The amount of condensate lost to the atmosphere (out of system) over a 24hr period (8hrs operational/16hrs standby) should be < 50mL

Part 43

Category: Catering and Hospitality Equipment

Technology: Commercial Laundry Driers

Commercial laundry driers are defined as products that automatically use mechanical motion and a heat source to dry laundry such as clothes, towels, sheets, etc.

Eligibility Criteria Overview

To be included on the ACA Specified List, a Commercial Laundry Drier must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

The load capacity of the drier must be a minimum of 14 kg.

3

Must comply with the Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS)10 and Waste Electrical and Electronic Equipment (WEEE)11 regulations.

4

The performance of the laundry drier must be as per the minimum values set out in Table 1 below

5

The drier must have a moisture sensing element that will automatically turn off the machine once the load is dry.

Table 1. Minimum drier energy performance values

Drier Type

Energy Efficiency (kWh per kg dryer load)

Air vented drier

0.51

Condensing drier

0.55

Part 44

Category: Catering & Hospitality Equipment

Technology: Commercial Laundry Washers

Commercial laundry washers are defined as products that automatically use mechanical motion to clean laundry such as clothes, towels, sheets, etc, and use water as the primary washing solution.

Eligibility Criteria Overview

To be included on the ACA Specified List, a Commercial Laundry Washer must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2

The load capacity of the washing machine must be a minimum of 10 kg

3

Must comply with the Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment (RoHS)12 and Waste Electrical and Electronic Equipment (WEEE)13 regulations.

4

The performance of the washing machine must be as per the minimum values set out in Table 1 below

Table 1: Minimum laundry washer energy performance values

Performance Type

Minimum Value for A Rating

Energy Consumption

0.15 kWh per kg wash load

Washing Efficiency Index

1.03

Part 45

Category: Motors and Drives

Technology: Permanent Magnet Motors

A Permanent Magnet Motor (PMM) is electric synchronous motor with a 3-phase wound stator, and a rotor that incorporates permanent magnets. When the wound stator is energised by a 3-phase alternating current, it creates a rotating magnetic field that causes the rotor to rotate synchronously with it, i.e. the rotor and the rotating electric field in the stator move at the same speed.

Eligibility Criteria Overview

To be included on the ACA Specified List, a permanent magnet motor must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

Must be a sinusoidally commutated, 3-phase permanent magnet synchronous motor with a rated shaft output of at least 0.75 kW

2

The motor must meet the efficiency requirements listed in Table 1

3

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

4

Appropriate operating and maintenance manuals must be available to the end user in order to maximise the achievement of any potential energy-efficiency gains

Table 1: Minimum Efficiency Criteria for Permanent Magnet Motors at 100% of max. continuous speed rating

Power Rating (kW)

Maximum continuous speed rating

Up to 325 rpm

326 rpm to 749 rpm

751 rpm to 1,000 rpm

1,001 rpmto 1,500 rpm

1,501 rpmto 3,000 rpm

Over 3,000 rpm

0. 75

71. 7

75. 3

78. 9

82. 5

80. 7

78. 9

1. 1

74. 8

77. 9

81. 0

84. 1

82. 7

81. 3

1. 5

76. 9

79. 7

82. 5

85. 3

84. 2

83. 1

2. 2

79. 5

81. 9

84. 3

86. 7

85. 9

85. 1

3. 0

81. 4

83. 5

85. 6

87. 7

87. 1

86. 5

4. 0

83. 2

85. 0

86. 8

88. 6

88. 1

87. 6

5. 5

84. 8

86. 4

88. 0

89. 6

89. 2

88. 8

7. 5

86. 5

87. 8

89. 1

90. 4

90. 1

89. 8

11. 0

88. 1

89. 2

90. 3

91. 4

91. 2

91. 0

15. 0

89. 4

90. 3

91. 2

92. 1

91. 9

91. 7

18. 5

89. 9

90. 8

91. 7

92. 6

92. 4

92. 2

22. 0

90. 6

91. 4

92. 2

93. 0

92. 7

92. 4

30. 0

91. 5

92. 2

92. 9

93. 6

93. 3

93. 0

37. 0

92. 1

92. 7

93. 3

93. 9

93. 7

93. 5

45. 0

92. 7

93. 2

93. 7

94. 2

94. 0

93. 8

55. 0

93. 1

93. 6

94. 1

94. 6

94. 3

94. 0

75. 0

93. 8

94. 2

94. 6

95. 0

94. 7

94. 4

90. 0

94. 3

94. 6

94. 9

95. 2

95. 0

94. 8

110. 0

94. 5

94. 8

95. 1

95. 4

95. 2

95. 0

132. 0

95. 0

95. 2

95. 4

95. 6

95. 4

95. 2

160. 0

95. 2

95. 4

95. 6

95. 8

95. 6

95. 4

200. 0

95. 4

95. 6

95. 8

96. 0

95. 8

95. 6

>200.0

95. 4

95. 6

95. 8

96. 0

95. 8

95. 6

Notes:

Where a particular motor size is not listed, the required minimum efficiency level for the next size up must be met.

Part 46

Category: Information and Communications Technology (ICT)

Technology: Blade Servers

A blade server is an optimised server computer of modular design for use in a shared blade chassis which can house multiple blade servers resulting in reduced space and energy usage. It will typically contain processors, memory, integrated network controllers, an optional fibre channel host bus adaptor (HBA) and other input/output (IO) ports. Blade servers can also optionally contain internal storage disks and cooling systems.

Eligibility Criteria Overview

To be included on the ACA Specified List, a Blade Server must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1

Must be marketed and sold as an enterprise Blade Server

2

Designed for, and listed as, supporting Blade Server operating systems and/or hypervisors, and targeted to run user-installed enterprise applications

3

Be capable of remote power-down

4

Must meet the relevant minimum performance to power ratios listed in Table 1, or scientifically equivalent measure

5

Must be supplied with a software management system that renders the server virtualisation capable

Table 1: Minimum server performance to power ratios

Server application

Minimum ratio*

Performance at low utilisation of less than or equal to 30%

> 900

Performance at moderate utilisation of greater than 30%, but less than 70%

> 1900

Performance at high utilisation of greater than or equal to 70%

> 2500

*Performance to Power Ratio

The ratio is based on the Standard Performance Evaluation Corporation (SPEC) industry standard benchmark performance test, SPECpower_ ssj2008 V1.10. Under this test the energy use of a blade server is tracked (plug power) while the server performs a defined sequence of operational tasks.

The metric required is calculated using the sum of outputs (throughput per Watt of power) and power consumed at 10% utilisation intervals, as shown below:

Performance to power ratio measured at low utilisation

= ssj ops(0%+10%+20%+30%) / power (0%+10%+20%+30%)

Performance to power ratio measured at moderate utilisation

= ssj ops(40%+50%+60%) / power (40%+50%+60%)

Performance to power ratio measured at high utilisation

= ssj ops(70%+80%+90%+100%) / power (70%+80%+90%+100%)

where:

• ssj ops = Workload at the specified utilisation level

• Power = Energy consumed in watts at specified utilisation level

Part 47

Category: Information and Communications Technology (ICT)

Technology: ICT Optimisation Solutions

ICT Optimisation Solutions are defined as systems and/or software that improve the power efficiency of enterprise ICT hardware systems and/or of ICT-related infrastructure resources.

ICT Optimisation Solutions are considered to include the following:

ICT power efficiency systems

ICT power efficiency systems are designed to automatically and continuously identify under-use of installed ICT hardware (e.g. servers), and facilitate their optimisation, with the aim of reducing overall power consumption.

Virtualisation solutions

Virtualisation solutions are software platforms that allow multiple OS applications to run simultaneously on one physical machine, with the aim of reducing the number of physical machines required.

Infrastructure power efficiency systems

Infrastructure power efficiency systems are designed to visually map, automate and optimise ICT-related infrastructure resources such as cooling, power and space, with the aim of reducing overall power consumption.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific ICT Optimisation Solution must meet all the relevant requirements as listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

ICT Power Efficiency Systems — Specific Eligibility Criteria

No.

Condition

1

Must have the capability of continuously collecting utilisation data from IT equipment using RS232, Ethernet or wireless connectivity

2

Must have the capability of identifying power-saving opportunities and outputting commands to a power management system

3

Must have the capability of presenting utilisation data in a graphical format, and calculating and presenting performance metrics

Virtualisation Solutions — Specific Eligibility Criteria

No.

Condition

4

Must be capable of virtualising from a physical server to a virtual system.14 The host physical server must be capable of accommodating a minimum of 20 virtual servers.

5

Physical servers, where included in the solution, must meet the separate ACA Enterprise Server eligibility criteria

6

Must be capable of powering down virtual machines and provisioning dynamically

Infrastructure Power Efficiency Systems — Specific Eligibility Criteria

No.

Condition

7

Must offer visual modelling of the physical, electrical and mechanical infrastructure within the data centre

8

Must offer a capacity management and infrastructure management capability

9

Must offer a data-centre efficiency reporting capability

Part 48

Category: Information and Communications Technology (ICT)

Technology: Enterprise Communication Equipment

Enterprise Communication Equipment is defined as equipment which enables a network of connected computers to communicate with each other. This equipment is made up of network devices which facilitate the intercommunication and resource sharing between the computers.

Enterprise Communication Equipment is considered to include the following:

Network Routers

A network router is a hardware device that interconnects wired or wireless networks. These may be subdivided into Core Routers, Carrier Edge/Ethernet Service Routers, and Multipurpose Routers.

Network Switches

A network switch is a hardware device that interconnects computers, forming a local area network (LAN).

Network Firewalls

A network firewall is a hardware device that protects a computer network from external unauthorised access.

Optical Transmission Equipment

Optical transmission equipment is communication hardware used for transmitting data over medium to long distances through a fibre-optic network.

Eligibility Criteria Overview

To be included on the ACA Specified List, the specific Enterprise Communication Equipment must meet all the relevant requirements listed below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

General Eligibility Criteria

(applicable to all Enterprise Communication equipment)

No.

Condition

1

Internal power supplies must achieve an 80 PLUS gold standard15 or scientific equivalent

2

External power supplies must be Energy Star-compliant16 or scientific equivalent

Network Router — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

3

Must achieve an ECR–VL17 energy consumption rating with variable load of less than or equal to 10 W/ Gbps

4

Must have variable-load energy-management capabilities

Network Switch — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

5

Must achieve an ECR–VL energy consumption rating with variable load of less than or equal to the values as set out in Table 1.

6

Must have variable-load energy-management capabilities

Network Firewall — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

7

Must achieve an ECR energy consumption rating of less than or equal to 3W/ Gbps

8

Must have variable-load energy-management capabilities

Optical Transmission Equipment — Specific Eligibility Criteria

(to be met in addition to the general eligibility criteria)

No.

Condition

9

Must achieve an ECR energy consumption rating with variable load of less than or equal to 3W/Gbps

10

Must have variable-load energy-management capabilities

Table 1: Network Switches — Maximum energy consumption values

Switch Type

Energy Consumption Rating(W/Gbps)

Stackable fixed port switches

3

6 port modular chassis switches

7. 5

6-12 port modular chassis switches

11

Notes:

W = Watts

Gbps = Giga bits per second

ECR = energy consumption rating (peak efficiency metric, W/Gbps)

= Ef/Tf (expressed in Watts per Gbps)

Where:

Ef = energy consumption (Watts) measured during the running test

Tf = maximum throughput (Gbps) achieved in the measurement

ECR-VL = energy efficiency metric over a variable-load cycle (W/Gbps)

(*E100 + *E50 + *E30 + * E10 + *Ei)

= ____________________

(*Tf + *T50 + *T30 + * T10)

Where:

, , , , are weight coefficients selected such as ( + + + + ) = 1

For test purposes the following values are used:

= 0.1

= 0.5

= 0.25

= 0.05

= 0.1

Tf = maximum throughput (Gbps) achieved in the measurement cycle

- T50 = Tf * 0.5

- T30 = Tf * 0.3

- T10 = Tf * 0.1

E100 = energy consumption under highest load accepted by System Under Test (SUT) (watts)

E50 = energy consumption under half load (watts)

E30 = energy consumption under 30% load (watts)

E10 = energy consumption under 10% load (watts)

Ei = energy consumption under 0% load (watts)

Part 49

Category: Heating and Electricity Provision

Technology: Biomass Boilers

Biomass Boilers provide an efficient, automatic method of generating hot water, steam or other heat-transporting fluids, using carbon-neutral biomass as the fuel source. The biomass boiler is considered as incorporating ancillary equipment such as control systems, fuel-feed system, fans and grit arrestors.

Eligibility criteria

To be included on the ACA Specified List, a biomass boiler must meet all the requirements set out below.

Note: Supporting documentation that clearly demonstrates ACA compliance according to the conditions below will be required as part of the ACA checking process. Detailed information on the types of documents accepted can be found in the separate Supporting Documentation guidelines.

No.

Condition

1.

All equipment and/or components must be CE-marked as required by the specific EU directive(s).

2.

Must be a minimum size of 50kW

3.

Appropriate operating and maintenance manuals must be available for the end-user as part of the main contract of sale in order to maximise the achievement of potential efficiency improvements.

4.

Must be equipped for automatic operation without the need for permanent supervision. This shall include:• Automatic start-up and shut-down • Ability to operate in slumber mode and to restart when the heating load demands • Automatic fuel loading commensurate with the heat/steam demand • Automatic ash removal • Automatic control of the burning rate commensurate with the heat demand

5.

Must incorporate a system to automatically prevent burn-back through the fuel-feed system.

6.

Must incorporate a fault-monitoring system which should be capable of communicating remotely a fault.The parameters to be monitored shall include:• Fuel shortage or blockage • Boiler shut-down • Boiler hot water/thermal fluid outlet temperature or steam pressure • Flue gas temperature

7.

To facilitate automatic tube cleaning, the boiler must incorporate a mechanical or pneumatic system for heat exchanger cleaning on the gas side.

8.

Must incorporate an automatic system to ‘trim’ the combustion air commensurate with the oxygen content of the flue gases so as to minimise ‘stack’ losses caused by excess air.

9.

Must incorporate a system to prevent over-heating of the water within the boiler in the event of a mains electricity failure.

10.

Efficiency and certified dust-emission levels, both measured in accordance with a recognised European standard, must achieve the minimum and maximum limits listed in Table 1 when burning wood pellets or wood chips.

Table 1. Thermal efficiency and emissions

Boiler rating

Thermal efficiency1

Dust emission2

Chips

Pellets

50 —150 kW

85%

90%

150

>150 — 500 kW

86%

91%

130

> 500 kW

87%

92%

120

1 The efficiencies shall be measured on a ‘net’ calorific value basis.

2 On an mg/Nm3 13 Vol.–%O2 basis”.

8. Part 2 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

VSD32650

3AUA0000039625

ACS310-03E- 01A3-4

Variable Speed Drive

ABB Ltd

VSD32651

3AUA0000039626

ACS310-03E- 02A1-4

Variable Speed Drive

ABB Ltd

VSD32652

3AUA0000039627

ACS310-03E- 02A6-4

Variable Speed Drive

ABB Ltd

VSD32653

3AUA0000039628

ACS310-03E- 03A6-4

Variable Speed Drive

ABB Ltd

VSD32654

3AUA0000039629

ACS310-03E- 04A5-4

Variable Speed Drive

ABB Ltd

VSD32655

3AUA0000039630

ACS310-03E- 06A2-4

Variable Speed Drive

ABB Ltd

VSD32656

3AUA0000039631

ACS310-03E- 08A0-4

Variable Speed Drive

ABB Ltd

VSD32657

3AUA0000039632

ACS310-03E- 09A7-4

Variable Speed Drive

ABB Ltd

VSD32658

3AUA0000039633

ACS310-03E- 13A8-4

Variable Speed Drive

ABB Ltd

VSD32659

3AUA0000039634

ACS310-03E- 17A2-4

Variable Speed Drive

ABB Ltd

VSD32660

3AUA0000039635

ACS310-03E- 25A4-4

Variable Speed Drive

ABB Ltd

VSD32661

3AUA0000039636

ACS310-03E- 34A1-4

Variable Speed Drive

ABB Ltd

VSD32662

3AUA0000039637

ACS310-03E- 41A8-4

Variable Speed Drive

ABB Ltd

VSD32663

3AUA00000039638

ACS310-03E- 48A4-4

Variable Speed Drive

ABB Ltd

VSD32664

3AUA0000058182

ACS355-03E- 01A2-4

Variable Speed Drive

ABB Ltd

VSD32665

3AUA0000058183

ACS355-03E- 01A9-4

Variable Speed Drive

ABB Ltd

VSD32666

3AUA0000058184

ACS355-03E- 02A4-4

Variable Speed Drive

ABB Ltd

VSD32667

3AUA0000058185

ACS355-03E- 03A3-4

Variable Speed Drive

ABB Ltd

VSD32668

3AUA0000058186

ACS355-03E- 04A1-4

Variable Speed Drive

ABB Ltd

VSD32669

3AUA0000058187

ACS355-03E- 05A6-4

Variable Speed Drive

ABB Ltd

VSD32670

3AUA0000058188

ACS355-03E- 07A3-4

Variable Speed Drive

ABB Ltd

VSD32671

3AUA0000058189

ACS355-03E- 08A8-4

Variable Speed Drive

ABB Ltd

VSD32672

3AUA0000058190

ACS355-03E- 12A5-4

Variable Speed Drive

ABB Ltd

VSD32673

3AUA0000058191

ACS355-03E- 15A6-4

Variable Speed Drive

ABB Ltd

VSD32674

3AUA0000058192

ACS355-03E- 23A1-4

Variable Speed Drive

ABB Ltd

VSD32675

3AUA0000058193

ACS355-03E- 31A0-4

Variable Speed Drive

ABB Ltd

VSD32676

3AUA0000058194

ACS355-03E- 38A0-4

Variable Speed Drive

ABB Ltd

VSD32677

3AUA0000058195

ACS355-03E- 44A0-4

Variable Speed Drive

ABB Ltd

”.

9. Part 3 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

LIG33282

IND 354

Excel Industry 354

3x54W T5 Industrial Luminaire

Excel Lighting

LIG33283

IND 454

Excel Industry 454

4X54W T5 Industrial Luminaire

Excel Lighting

LIG33284

IND 349

Excel Industry 349

3x49W T5 Industrial Luminaire

Excel Lighting

LIG33285

IND 449

Excel Industry 449

4x49W T5 Industrial Luminaire

Excel Lighting

LIG33286

IND 380

Excel Industry 380

3x80W T5 Industrial Luminaire

Excel Lighting

LIG33287

IND 480

Excel Industry 480

4x80W T5 Industrial Luminaire

Excel Lighting

LIG31992

CLASSIC ASN PAR-V 414

CLASSIC ASN PAR-V 414

SURFACE 4 X 14W T5 LUMINAIRE

ACEC Distributors

LIG31993

DL VISION ECO 217

DL VISION ECO 217

2X17W PL-R ECO DOWNLIGHT

ACEC Distributors

LIG31994

FIVE 328-RBV 328

FIVE 328-RBV 328

RECESSED 3 X 28W T5 PAR LOUVRE

ACEC Distributors

LIG31995

PLAST 228PRISMA

PLAST 228PRISMA

SURFACE 2 x 28W T5 OPL FLATBACK

ACEC Distributors

LIG31996

PLAST 235PRISMA

PLAST 235PRISMA

SURFACE 2 x 28W T5 OPL FLATBACK

ACEC Distributors

LIG31997

PLAST 249PRISMA

PLAST 249PRISMA

SURFACE 2 x 28W T5 OPL FLATBACK

ACEC Distributors

LIG31998

PLAST 254PRISMA

PLAST 254PRISMA

SURFACE 2 x 28W T5 OPL FLATBACK

ACEC Distributors

LIG32134

ELC2

2ft Linear Converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32135

ELC4

4ft Linear Converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32136

ELC5

5ft Linear Converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32137

ELC6

6ft Linear Converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32138

ELC8

8ft Linear Converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32139

ELCQ

2ft Quad Linear converter

A T5 fluroescent tube adaptor to convert T8 & T12 fluorescent tube fittings

E-Matic

LIG32166

T230

T230

2X24W RECESSED

Philips

LIG32167

MRS551

MRS551

35W CDM TRACK SPOT

Philips

LIG32179

ACDC1068/FX

EVO 100 Fixed

Recessed downlighter with fixed reflector

ACDC LED Ltd.

LIG32180

ACDC1068/AD

EVO 100 Adjustable

Recessed downlighter with adjustable reflector

ACDC LED Ltd.

LIG32181

ACDC1068/TR

EVO 90 Trimless

Recessed trimless downlighter for plaster ceilings

ACDC LED Ltd.

LIG29100

RBP436/2

Cleanline 236

Cleanroom luminaire IP54 with aluminium back reflectors

ACEC Distributors

LIG29103

Plast H 249 prisma

Plast H 249P

Linear Flat back luminaire with prismatic polycarbonate diffuser

ACEC Distributors

LIG29107

Plast P236 HF prisma

Plast P 236P

Linear Flat back luminaire with prismatic polycarbonate diffuser

ACEC Distributors

LIG29108

Plast P236 HF opal

Plast P 2360

Linear Flat back luminaire with opal polycarbonate diffuser

ACEC Distributors

LIG29196

SR10-10

SunRAY10

Intelligent LED High Bay Light, 110W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG29197

SR10-8

SunRAY8

Intelligent LED High Bay Light, 88W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG29198

SR6-6

SunRAY6

Intelligent LED Modular Light, 66W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG29199

SR6-4

SunRAY4

Intelligent LED Modular Light, 44W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG29200

SR6-2

SunRAY2

Intelligent LED Modular Light, 22W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG29201

SR6-1

SunRAY1

Intelligent LED Modular Light, 11W, automated & programmable power output increase/ decrease & on/off dimming & scheduling capabilities, light adjusting photocell & LED automatic temperature control

Low Energy Designs Limited

LIG31225

LUCI V01

LUCI

LED Under Canopy Illumination. LED Energy Saving

Bever Innovations B.V.

LIG31226

LIN454Z

LINERGY454W

Flourescent T5 Low bay luminaire with open area optics

Cooper Lighting & Safety Ltd.

LIG31227

LIN480Z

LINERGY480W

Flourescent T5 Low bay luminaire with open area optics

Cooper Lighting & Safety Ltd.

LIG31228

LIN654Z

LINERGY654W

Flourescent T5 Low bay luminaire with open area optics

Cooper Lighting & Safety Ltd.

LIG31229

LINR454Z

LINERGY454R

Flourescent T5 Low bay luminaire with racking aisle optics

Cooper Lighting & Safety Ltd.

LIG31230

LINR480Z

LINERGY480R

Flourescent T5 Low bay luminaire with racking aisle optics

Cooper Lighting & Safety Ltd.

LIG31231

LINR654Z

LINERGY654R

Flourescent T5 Low bay luminaire with racking aisle optics

Cooper Lighting & Safety Ltd.

LIG31232

MDI414Z

ModulayDI414

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31233

MDI224Z

ModulayDI224

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31234

MDI240Z

ModulayDI240

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31235

MDI155Z

ModulayDI155

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31236

MDI255Z

ModulayDI1255

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31237

WLT128ZX

WaveliteT5128

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31238

WLT228ZX

WaveliteT5228

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31239

WLT135ZX

WaveliteT5153

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31240

WLT235ZX

WaveliteT5235

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31241

WLT154ZX

WaveliteT5154

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31242

WLT149ZX

WaveliteT5149

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31243

WLT249ZX

WaveliteT5249

Surface mounted shallow profiled IP44 prismatic luminaire

Cooper Lighting & Safety Ltd.

LIG31244

SYWV128Z

Syntesis 128V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31245

SYWV228Z

Syntesis 228V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31246

SYWV135Z

Syntesis 135V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31247

SYWV235Z

Syntesis 235V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31248

SYWR128Z

Syntesis 128R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31249

SYWR228Z

Syntesis 228R

Extruded aluminium Supended T5 up/downlight luminaire withlow brightness louvre

Cooper Lighting & Safety Ltd.

LIG31250

SYWR135Z

Syntesis 135R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31251

SYWR235Z

Syntesis 235R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31252

SYWV154Z

Syntesis 154V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31253

SYWV254Z

Syntesis 254V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31254

SYWV149Z

Syntesis 149V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31255

SYWV249Z

Syntesis 249V

Extruded aluminium Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31256

SYWR154Z

Syntesis 154R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31257

SYWR254Z

Syntesis 254R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31258

SYWR149Z

Syntesis 149R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31259

SYWR249Z

Syntesis 249R

Extruded aluminium Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31260

LLWV128Z

Lasaline128V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31261

LLWV228Z

Lazeline228V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31262

LLWV135Z

Lazeline135V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31263

LLWV235Z

Lazeline235V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31264

LLWR128Z

Lazeline128R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31265

LLWR228Z

Lazeline228R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31266

LLWR135Z

Lazeline135R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31267

LLWR235Z

Lazeline235R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31268

LLWV154Z

Lazeline154V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31269

LLWV254Z

Lazeline254V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31270

LLWV149Z

Lazeline149V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31271

LLWV249Z

Lazeline249V

Square section steel Supended T5 up/downlight luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31272

LLWR154Z

Lazeline154R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31273

LLWR254Z

Lazeline254R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31274

LLWR149Z

Lazeline149R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31275

LLWR249Z

Lazeline249R

Square section steel Supended T5 up/downlight luminaire with low brightness louvre

Cooper Lighting & Safety Ltd.

LIG31276

CFL414Z

Combiform Layin 414

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31277

CFL224Z

Combiform Layin 224

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31278

CFL140Z

Combiform Layin 140

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31279

CFL240Z

Combiform Layin 240

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31280

CFL155Z

Combiform Layin 155

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31281

CFL255Z

Combiform Layin 255

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31282

MSFM314Z

Moduspec T5FM314

T5 Recessed modular luminaire with LG7 mirror louver and solid pannel

Cooper Lighting & Safety Ltd.

LIG31283

MSFM414Z

Moduspec T5FM414

T5 Recessed modular luminaire with LG7 mirror louver and solid pannel

Cooper Lighting & Safety Ltd.

LIG31284

MSPM314Z

Moduspec T5PM314

T5 Recessed modular luminaire with LG7 mirror louver and perforated pannel

Cooper Lighting & Safety Ltd.

LIG31285

MSPM414Z

Moduspec T5PM414

T5 Recessed modular luminaire with LG7 mirror louver and perforated pannel

Cooper Lighting & Safety Ltd.

LIG31286

MSFS314Z

Moduspec T5FS314

T5 Recessed modular luminaire with LG7 satin louver and solid pannel

Cooper Lighting & Safety Ltd.

LIG31287

MSFS414Z

Moduspec T5FS414

T5 Recessed modular luminaire with LG7 satin louver and solid pannel

Cooper Lighting & Safety Ltd.

LIG31288

MSPS314Z

Moduspec T5PS314

T5 Recessed modular luminaire with LG7 satin louver and perforated pannel

Cooper Lighting & Safety Ltd.

LIG31289

MSPS414Z

Moduspec T5PS414

T5 Recessed modular luminaire with LG7 satin louver and perforated pannel

Cooper Lighting & Safety Ltd.

LIG31290

MSTS314Z

Moduspec T5TS314

T5 Recessed modular luminaire with LG7 satin louver and tilted perforated pannel

Cooper Lighting & Safety Ltd.

LIG31291

MSTS414Z

Moduspec T5TS414

T5 Recessed modular luminaire with LG7 satin louver and tilted perforated pannel

Cooper Lighting & Safety Ltd.

LIG31292

ML314ZT/MLG318

Modulay T5GP314

Recessed T5 lay in Modular luminaire with General purpos louvre

Cooper Lighting & Safety Ltd.

LIG31293

ML414ZT/MLGP418

Modulay T5GP414

Recessed T5 lay in Modular luminaire with General purpos louvre

Cooper Lighting & Safety Ltd.

LIG31294

ML314ZT/MLV318

Modulay T5V314

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31295

ML414ZT/MLV418

Modulay T5V414

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31296

ML328ZT/MLG336

Modulay T5GP328

Recessed T5 lay in Modular luminaire with General purpose louvre

Cooper Lighting & Safety Ltd.

LIG31297

ML428ZT/MLG436

Modulay T5GP428

Recessed T5 lay in Modular luminaire with General purpose louvre

Cooper Lighting & Safety Ltd.

LIG31298

ML328ZT/MLV336

Modulay T5V328

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31299

ML428ZT/MLV436

Modulay T5V428

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31300

ML354ZT/MLG336

Modulay T5GP354

Recessed T5 lay in Modular luminaire with General purpose louvre

Cooper Lighting & Safety Ltd.

LIG31301

ML454ZT/MLG436

Modulay T5GP454

Recessed T5 lay in Modular luminaire with General purpose louvre

Cooper Lighting & Safety Ltd.

LIG31302

ML354ZT/MLV336

Modulay T5V354

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31303

ML454ZT/MLV436

Modulay T5V454

Recessed T5 lay in Modular luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31304

BALI224Z

BALI224

Recessed modular indirect/direct with pendant LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31305

BALI155Z

BALI155

Recessed modular indirect/direct with pendant LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31306

HAL414Z

HAL414

Semi recessed modular luminaire with drpoed LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31307

HAL424Z

HAL424

Semi recessed modular luminaire with drpoed LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31308

CFP140Z

Combiform CFP140

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31309

CFP155Z

Combiform CFP155

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31310

CFP240Z

Combiform CFP240

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31311

CFP25Z

Combiform CFP255

Recessed Modular indirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31312

ILDCFP240R

INTELLECT DIGITAL COMBIFORM CFP240

Intellect digital recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31313

ILDCFP255R

INTELLECT DIGITAL COMBIFORM CFP255

Intellect digital recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31314

ILDCFPS255R

INTELLECT DIGITAL COMBIFORM CFPS255

Intellect digital semi recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31315

ILRCFP240R

INTELLECT REGULATOR COMBIFORM CFP240

Intellect regulator recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31316

ILRCFP255R

INTELLECT REGULATOR COMBIFORM CFP255

Intellect regulator recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31317

ILRCFPS255R

INTELLECT REGULATOR COMBIFORM CFPS255

Intellect regulator semi recessed Modular luminaire ndirect/direct with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31318

CVX241Z

Chevinplus CVX241

Surface mounted luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31319

CVX242Z

Chevinplus CVX242

Surface mounted luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31320

CVX244Z

Chevinplus CVX244

Surface mounted luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31321

CXV261Z

Chevinplus CVX261

Surface mounted luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31322

CVX262Z

Chevinplus CVX262

Surface mounted luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31323

CVXR41Z

Chevinplus CVXR41

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31324

CVXR42Z

Chevinplus CVXR42

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31325

CVXR44Z

Chevinplus CVXR44

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31326

CVXR51Z

Chevinplus CVXR51

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31327

CVXR52Z

Chevinplus CVXR52

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31328

CVXR61Z

Chevinplus CVXR61

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31329

CVXR62Z

Chevinplus CVXR62

Surface mounted luminaire with general propose louvre

Cooper Lighting & Safety Ltd.

LIG31330

WAVL128Z

WAVEFORM WAVL128

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31331

WAVL228Z

WAVEFORM WAVL228

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31332

WAVL154Z

WAVEFORM WAVL154

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31333

WAVL254Z

WAVEFORM WAVL254

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31334

WAVL135Z

WAVEFORM WAVL135

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31335

WAVL235Z

WAVEFORM WAVL235

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31336

WAVL149Z

WAVEFORM WAVL149

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31337

WAVL249Z

WAVEFORM WAVL249

Surface direct/indirect luminaire with LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31338

WAVP128Z

WAVEFORM WAVP128

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31339

WAVP228Z

WAVEFORM WAVP228

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31340

WAVP154Z

WAVEFORM WAVP154

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31341

WAVP135Z

WAVEFORM WAVP135

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31342

WAVP235Z

WAVEFORM WAVP235

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31343

WAVP149Z

WAVEFORM WAVP149

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31344

WAVP249Z

WAVEFORM WAVP249

Surface direct/indirect luminaire with perforated basket

Cooper Lighting & Safety Ltd.

LIG31345

VYP128Z

VARSITY T5 VYP128

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31346

VYP228Z

VARSITY T5 VYP228

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31347

VYP135Z

VARSITY T5 VYP135

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31348

VYP235Z

VARSITY T5 VYP235

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31349

VYP149Z

VARSITY T5 VYP149

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31350

VYP249Z

VARSITY T5 VYP249

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31351

VYP136Z

VARSITY T8 VYP136

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31352

VYP236Z

VARSITY T8 VYP236

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31353

VYP158Z

VARSITY T8 VYP158

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31354

VYP258Z

VARSITY T8 VYP258

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31355

VYP170Z

VARSITY T VYP170

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31356

VYP270Z

VARSITY T8 VYP270

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31357

ILDVYP228R

INTELLECT VARSITY T5 VYP228

Intellect digital surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31358

ILDVYP235R

INTELLECT VARSITY T5 VYP235

Intellect digital surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31359

ILDVYP249R

INTELLECT VARSITY T5 VYP249

Intellect digital surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31360

ILDVYP236R

INTELLECT VARSITY T8 VYP236

Intellect digital surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31361

ILDVYP258R

INTELLECT VARSITY T8 VYP258

Intellect digital surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31362

VYSP128Z

VARSITY SCHOOL T5 VYSP128

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31363

VYSP228Z

VARSITY SCHOOL T5 VYSP228

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31364

VYSP135Z

VARSITY SCHOOL T5 VYSP135

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31365

VYSP235Z

VARSITY SCHOOL T5 VYSP235

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31366

VYSP149Z

VARSITY SCHOOL T5 VYSP149

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31367

VYSP249Z

VARSITY SCHOOL T5 VYSP249

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31368

VYSP136Z

VARSITY SCHOOL T8 VYSP136

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31369

VYSP236Z

VARSITY SCHOOL T8 VYSP236

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31370

VYSP158Z

VARSITY SCHOOL T8 VYSP158

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31371

VYSP258Z

VARSITY SCHOOL T8 VYSP258

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31372

VYSP170Z

VARSITY SCHOOL T8 VYSP170

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31373

VYSP270Z

VARSITY SCHOOL T8 VYSP270

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31374

ILDVYSP228R

INTELLECT VARSITY SCHOOL T5 VYSP228

surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31375

ILDVYSP235R

INTELLECT VARSITY SCHOOL T5 VYSP235

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31376

ILDVYSP249R

INTELLECT VARSITY SCHOOL T5 VYSP249

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31377

ILDVYSP236R

INTELLECTVARSITY SCHOOL T8 VYSP236

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31378

ILDVYSP258R

INTELLECT VARSITY SCHOOL T8 VYSP258

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31379

VYHP128Z

VARSITY HOSPITAL T5 VYHP128

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31380

VYHP228Z

VARSITY HOSPITAL T5 VYHP228

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31381

VYHS135Z

VARSITY HOSPITAL T5 VYHP135

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31382

VYHP235Z

VARSITY HOSPITAL T5 VYHP235

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31383

VYHP149Z

VARSITY HOSPITAL T5 VYHP149

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31384

VYHP249Z

VARSITY HOSPITAL T5 VYHP249

Surface T5 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31385

VYHP136Z

VARSITY HOSPITAL T5 VYHP136

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31386

VYHP236Z

VARSITY HOSPITAL T5 VYHP236

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31387

VYHP158Z

VARSITY HOSPITAL T5 VYHP158

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31388

VYHP258Z

VARSITY HOSPITAL T5 VYHP258

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31389

VYHP170Z

VARSITY HOSPITAL T5 VYHP170

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31390

VYHP270Z

VARSITY HOSPITAL T5 VYHP270

Surface T8 luminare with polycarbonate prismatic controller

Cooper Lighting & Safety Ltd.

LIG31391

MCX240Z/MXM22

MODUCELL 240

Recessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31392

MCX255Z/ MVXM22

MODUCELL255

Recessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31393

MCFX236Z/ MVFXM22

MODUCELL236

Recessed 500 x 500mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31394

ILDMCX240R/ ILMVXM22

INTELLECT DIGITAL MODUCELL 240

Intellect digital recessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31395

ILDMCX255R/ ILMVXM22

INTELLECT DIGTAL MODUCELL255

Intellect digital recessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31396

ILDMCFX236R/ ILMVFXM22

INTELLECT DIGITAL MODUCELL236

Intellect digital recessed 500 x 500mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31397

ILRMCX240R/ ILMVXM22

INTELECT REGULATOR MODUCELL 240

Intellect regulatorrecessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31398

ILRMCX255R/ ILMVXM22

INTELLECT REGULATOR MODUCELL255

Intellect regulator recessed 600 x 600mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31399

ILRMCFX236R/ ILMVFXM22

INTELLECT REGULATOR MODUCELL236

Intellect regulator recessed 500 x 500mm modular luminaire with 16 cell LG7 louvre

Cooper Lighting & Safety Ltd.

LIG31400

AFXS2240Z

AEROFORM 240

Recessed modular luminare with LG7 Louver

Cooper Lighting & Safety Ltd.

LIG31401

AFXS2255Z

AEROFORM 255

Recessed modular luminare with LG7 Louver

Cooper Lighting & Safety Ltd.

LIG31402

ILDAFXS2240R

INTELLECT DIGITAL AEROFORM 240

Intellect digitalRecessed modular luminare with LG7 Louver

Cooper Lighting & Safety Ltd.

LIG31403

ILDAFXS2255R

INTELLECT DIGITAL AEROFORM 255

Intellect digitalRecessed modular luminare with LG7 Louver

Cooper Lighting & Safety Ltd.

LIG31404

ILRAFXS2240R

INTELLECT REGULAR AEROFORM 240

Intellect digitalRecessed modular luminare with LG7 Louver

Cooper Lighting & Safety Ltd.

LIG31406

TFC118Z

TUFFLITE TFC118

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31407

TFC218Z

TUFFLITE TFC218

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31408

TFC136Z

TUFFLITE TFC136

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31409

TFC236Z

TUFFLITE TFC236

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31410

TFC158Z

TUFFLITE TFC158

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31411

TFC258Z

TUFFLITE TFC258

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31412

TFC170Z

TUFFLITE TFC170

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31413

TFC270Z

TUFFLITE TFC270

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31414

TFC128Z

TUFFLITE TFC128

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31415

TFC228Z

TUFFLITE TFC228

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31416

TFC135Z

TUFFLITE TFC135

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31417

TFC235Z

TUFFLITE TFC235

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31418

TFC149Z

TUFFLITE TFC149

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31419

TFC249Z

TUFFLITE TFC249

IP65 Corrosion Proof luminaire with GRP housing and Acrylic diffuser

Cooper Lighting & Safety Ltd.

LIG31420

TFW118Z

TUFFLITE TFW118

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31421

TFW218Z

TUFFLITE TFW218

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31422

TFW136Z

TUFFLITE TFW136

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31423

TFW236Z

TUFFLITE TFW236

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31424

TFW158Z

TUFFLITE TFW158

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31425

TFW258Z

TUFFLITE TFW258

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31426

TFW170Z

TUFFLITE TFW170

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31427

TFW270Z

TUFFLITE TFW270

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31428

TFW128Z

TUFFLITE TFW128

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31429

TFW228Z

TUFFLITE TFW228

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31430

TFW135Z

TUFFLITE TFW135

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31431

TFW235Z

TUFFLITE TFW235

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31432

TFW149Z

TUFFLITE TFW149

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31433

TFW249Z

TUFFLITE TFW249

IP65 Corrosion Proof luminaire with Polycarbonate and housing and diffuser

Cooper Lighting & Safety Ltd.

LIG31513

MASTER LEDbulb 6W E27 4200K 230V A55

MASTER LEDbulb 6W E27 4200K

LED Lamp

Philips

LIG31515

MASTER LEDbulb 6W E27 2700K 230V A55

MASTER LEDbulb 6W E27 2700K

LED Lamp

Philips

LIG33741

Plast H 280 Prisma

Plast H 280P

Linear Flatback luminaire with polycarbonate prismatic diffuser

ACEC Distributors

LIG33742

Plast H 254 Prisma

Plast H 254P

Linear Flatback luminaire with polycarbonate prismatic diffuser

ACEC Distributors

LIG33743

Plast H 235 Prisma

Plast H 235P

Linear Flatback luminaire with polycarbonate prismatic diffuser

ACEC Distributors

LIG33744

Plast H 228 Prisma

Plast H 228P

Linear Flatback luminaire with polycarbonate prismatic diffuser

ACEC Distributors

”.

10. Part 4 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

LCO30110

Hid control unit

Hid light manager

High intensity discharge unit for the control and dimming of metal halides, high and low pressure sodiums and mercury vapour lights.

Power-save Energy Corp

LCO30772

eDin Control System

eDin

Din allows individual modules to be selected to create the desired lighting system. eDin provides solutions for simple standalone systems to a fully connected and integrated multi-room systems.

Mode Lighting Ltd.

”.

11. Part 5 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

BEM32688

MONI/ 000006

Eniscope Energy Management System

A computer based energy management system which monitors and controls energy use providing salient real time information and historical trend data.

Enigin Plc

BEM33476

M90211

Power Studio

Energy supervision software allowing • monitoring in real time • Recording and printing of logs • XML Server • Multiple Users • Data can be exported to external applications

Circutor

”.

12. Part 6 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

EST31169

EqualLogic PS6010S

PS6010S

PS6010 iSCSI SAN with either 8 or 16 SSD drives, and up to 1.6TB per array

Dell

”.

13. Part 7 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

ESE31518

Primergy RX300 S6

S26361-K1344-V201

RX300 S6, 2x Intel 55xx CPU, 144GB DDR3 Memory Rack Server

fujitsu

ESE31519

Primergy TX150 S7

S26361-K1265-V401

TX150 S7, Ix Intel CPU, Tower Server

fujitsu

”.

14. Part 10 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

CDC31990

1-M00024G

GDN.C.48.M24

20kW Guardian Access Power System for up to 10 x 2kW Rectifiers. ACC System controller. Distribution with up to 6 x battery MCBs, 24 x load MCBs. 400 or 500A LVD. PLD option. Up to 4 battery shelves. Optional Battery Temperature and Symmetry monitoring.

Power-One

CDC31991

1-M00029G

GDN.C.48.M29

96kW Guardian Central Power System. Single or twin cabinet with up to 24 x 2kW Rectifiers per cabinet. ACC System controller. Battery Distribution options foir MCCB and NH fuses. Load distribution options for MCB, MCCB and NH fuses. LVD and PLD options. Battery Temperature and Symmetry monitoring.

Power-One

”.

15. Part 14 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

WTU33748

Aurora PVI-3600-OUTD-IE-F-W

Aurora PVI-3600 Outdoor Inverter

Wind Turbine Inverter

Power-One

WTU33749

PVI-6000-OUTD-IE-W

Aurora PVI-6000

Wind Turbine Inverter

Power-One

WTU33751

SMA WB2500

SMA Windboy 2500 Inverter

WInd Turbine Inverter

SMA

WTU33752

SMA WB3000

SMA Windy Boy 3000 Inverter

Wind Turbine Inverter

SMA

WTU33756

SMA WB6000A

SMA Windy Boy WB6000A

Wind Energy Inverter

SMA

”.

16. Part 18 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

PSY33757

SMC5000A

SMA SMC 5000A

Photovoltiac Inverter

SMA

PSY33762

SB 1100

SMA Sunny Boy 1100

PV inverter 1.1kW

SMA

PSY33763

SB 1700

SMA Sunny Boy 1700

PV Inverter 1.7kW

SMA

PSY33764

SB 2500

SMA Sunny Boy 2500

PV Inverter 2.5kW

SMA

PSY33765

SB 3000

SMA Sunny Boy 3000

PV Inverter 3kW

SMA

PSY33745

SMC 4600A

Sunny Mini Central 4600A

PV Inverter

SMA

PSY33746

Sunny Boy 1200

Sunny Boy 1200

PV Inverter

SMA

PSY33747

Sunny Boy 3300

Sunny Boy 3300

PV Inverter

SMA

PSY33717

Sunmaster XS2000

Sunmaster XS2000

PV Inverter

Mastervolt

PSY33720

Sunmaster XS3200

Sunmaster XS3200

PV Inverter

Mastervolt

PSY33721

Sunmaster XS4300

Sunmaster XS4300

PV Inverter

Mastervolt

PSY33722

Sunmaster XS6500

Sunmaster XS6500

PV Inverter

Mastervolt

PSY33723

Sunmaster XL10

Sunmaster XL10

PV Inverter

Mastervolt

PSY33724

Sunmaster XL15

Sunmaster XL15

PV Inverter

Mastervolt

PSY33725

Fronius IG15

Fronius IG15

PV Inverter

Fronius

PSY33726

Fronius IG20

Fronius IG20

PV Inverter

Fronius

PSY33727

Fronius IG30

Fronius IG30

PV Inverter

Fronius

PSY33728

Fronius IG40

Fronius IG40

PV Inverter

Fronius

PSY33729

Fronius IG60HV

Fronius IG60HV

PV Inverter

Fronius

PSY33730

Fronius IG Plus 35

Fronius IG Plus 35

PV Inverter

Fronius

PSY33731

Fronius IG Plus 50

Fronius IG Plus 50

PV Inverter

Fronius

PSY33732

Fronius IG Plus 70

Fronius IG Plus 70

PV Inverter

Fronius

PSY33733

Fronius IG Plus 100

Fronius IG Plus 100

PV Inverter

Fronius

PSY33734

Fronius IG Plus 120

Fronius IG Plus 120

PV Inverter

Fronius

PSY33735

Fronius IG Plus 150

Fronius IG Plus 150

PV Inverter

Fronius

PSY30799

PV-Modul SCHOTT POLY 225, 225Wp

Schott Poly 225

poly PV panel

SCHOTT Solar AG

PSY31221

A-277P

Atersa Solar PV Panel A-277P

Solar Photovoltaic Panel

Atersa

PSY31222

A-214P

Atersa Solar PV Panel A-214P

Solar Photovoltaic Panel

Atersa

PSY31223

A-222P

Atersa Solar PV Panel A-222P

Solar Photovoltaic System

Atersa

PSY31224

A-230P

Atersa Solar PV Panel A-230P

Solar Photovoltaic System

Atersa

PSY32935

SB3800

Sunnyboy SB3800

3800 watt Grid-Connected Solar PV Inverter

SMA

PSY32936

SB 4200TL HC

Sunnyboy SB 4200TL HC

4200 watt Grid-connected Multi-string Solar PV inverter

SMA

PSY32937

SB 5000TL HC

Sunnyboy SB 5000TL HC

5000 watt Grid-Connected Multi-string Solar PV inverter

SMA

PSY32938

SMC 5000A

Sunny Mini Central SMC 5000A

5000 watt Grid-Connected Solar PV Inverter

SMA

PSY32939

SMC 6000A

Sunny Mini Central SMC 6000A

6000 watt Grid-Connected Solar PV Inverter

SMA

PSY32940

SMC 7000 HV

Sunny Mini Central SMC 7000 HV

7000 watt Grid-Connected Solar PV Inverter

SMA

PSY32941

SMC 6000 TL

Sunny Mini Central SMC 6000TL

6000 watt Grid-connected Solar PV Inverter

SMA

PSY32942

SMC 7000TL

Sunny Mini Central SMC 7000TL

7000 watt Grid-connected Solar PV Inverter

SMA

PSY32943

SMC 8000TL

Sunny Mini Central SMC 8000TL

8000 watt Grid-connected Solar PV Inverter

SMA

”.

17. Part 22 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

HHR32643

Brink-HRM 300

Brink Renovent HR-M

An MVHR unit capable of delivering up to300m3/h @ 250Pa. Unit incorporates-constant flow DC fan motors, a crosscounter flow exchanger and integrated thermostats.

Brink Climate Systems Ireland Ltd

HHR32644

Brink-HRL 400

Brink Renovent HR-L

An MVHR unit capable of delivering up to400m3/h @ 275Pa. Unit incorporates-constant flow DC fan motors, a crosscounter flow exchanger and integrated thermostats.

Brink Climate Systems Ireland Ltd

HHR32645

Brink-HRB/M 300

Brink Renovent HRB-M

An MVHR unit capable of delivering up to300m3/h @ 250Pa. Unit incorporates-constant flow DC fan motors, a crosscounter flow exchanger and integrated thermostats. 100% Summer bypass.

Brink Climate Systems Ireland Ltd

HHR32646

Brink-HRB/L 400

Brink Renovent HRB-L

An MVHR unit capable of delivering up to400m3/h @ 275Pa. Unit incorporates-constant flow DC fan motors, a crosscounter flow exchanger and integrated thermostats. 100% summer bypass.

Brink Climate Systems Ireland Ltd

”.

18. Part 24 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

PUM31019

107390801

SV405F11M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31020

107390811

SV406F11M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31021

107390821

SV407F11M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31022

107390831

SV408F15M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31023

107390841

SV409F15M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31024

101500861

SV411F22M/P ELP 220-240 50

Vertical Multistage Centrifugal

ITT Ireland

PUM31029

107390551

SV405F11T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31030

107390561

SV406F11T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31031

107390571

SV407F11T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31032

107390581

SV408F15T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31033

107390591

SV409F15T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31034

107390611

SV411F22T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31042

107391221

SV802F11M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31043

107391231

SV803F15M/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31044

101501241

SV804F22M/P ELP 220-240 50

Vertical Multistage Centrifugal

ITT Ireland

PUM31045

101501251

SV805F22M/P ELP 220-240 50

Vertical Multistage Centrifugal

ITT Ireland

PUM31046

107391021

SV802F11T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31047

107391031

SV803F15T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31048

107391041

SV804F22T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31049

107391051

SV805F22T/A

Vertical Multistage Centrifugal

ITT Ireland

PUM31050

101501061

SV806F30T/P ELP 23/40

Vertical Multistage Centrifugal

ITT Ireland

PUM31051

101501081

SV808F40T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31052

101501091

SV809F40T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31053

101501111

SV811F55T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31054

101501121

SV812F55T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31055

101501141

SV814F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31056

101501161

SV816F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31073

101570051

SV3302F55T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31074

101570061

SV3303/2F55T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31075

101570071

SV3303/1F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31076

101570081

SV3303F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31077

101570091

SV3304/2F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31078

101570101

SV3304/1F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31079

101570111

SV3304F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31080

101570121

SV3305/2F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31081

101570131

SV3305/1F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31082

101570141

SV3305F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31083

101570151

SV3306/2F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31084

101570161

SV3306/1F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31085

101570171

SV3306F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31086

101570181

SV3307/2F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31087

101570191

SV3307/1F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31088

101570201

SV3307F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31089

101570211

SV3308/2F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31090

101570221

SV3308/1F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31091

101570231

SV3308F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31092

101570241

SV3309/2F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31093

101570251

SV3309/1F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31094

101570261

SV3309F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31095

101570271

SV3310/2F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31096

102700281

SV3310/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31097

102700291

SV3310F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31098

102700301

SV3311/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31099

102700311

SV3311/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31100

102700321

SV3311F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31101

102700331

SV3312/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31102

102700341

SV3312/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31103

102700351

SV3312F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31104

102700361

SV3313/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31105

102700371

SV3313/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31106

101572011

SV4601/1F30T/P ELP 23/40

Vertical Multistage Centrifugal

ITT Ireland

PUM31107

101572021

SV4601F40T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31108

101572031

SV4602/2F55T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31109

101572041

SV4602F75T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31110

101572051

SV4603/2F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31111

101572061

SV4603F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31112

101572071

SV4604/2F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31113

101572081

SV4604F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31114

101572091

SV4605/2F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31115

101572101

SV4605F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31116

101572111

SV4606/2F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31117

101572121

SV4606F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31118

102702131

SV4607/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31119

102702141

SV4607F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31120

102702151

SV4608/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31121

102702161

SV4608F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31122

102702171

SV4609/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31123

102702181

SV4609F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31124

102702191

SV4610/2F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31125

102702201

SV4610F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31126

102702211

SV4611/2F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31127

102702221

SV4611F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31128

102702231

SV4612/2F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31129

102702241

SV4612F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31130

102702251

SV4613/2F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31131

101574011

SV6601/1F40T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31134

101574041

SV6602/1F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31135

101574051

SV6602F110T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31136

101574061

SV6603/2F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31137

101574071

SV6603/1F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31138

101574081

SV6603F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31139

101574091

SV6604/2F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31140

101574101

SV6604/1F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31141

101574111

SV6604F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31142

102704121

SV6605/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31143

102704131

SV6605/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31144

102704141

SV6605F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31145

102704151

SV6606/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31146

102704161

SV6606/1F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31147

102704171

SV6606F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31148

102704181

SV6607/2F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31149

102704191

SV6607/1F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31150

102704201

SV6607F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31151

102704211

SV6608/2F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31152

102704221

SV6608/1F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31153

102704231

SV6608F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31157

101576041

SV9202F150T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31158

101576051

SV9203/2F185T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31159

101576061

SV9203F220T/P ELP 40/69

Vertical Multistage Centrifugal

ITT Ireland

PUM31160

102706071

SV9204/2F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31161

102706081

SV9204F300T

Vertical Multistage Centrifugal

ITT Ireland

PUM31162

102706091

SV9205/2F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31163

102706101

SV9205F370T

Vertical Multistage Centrifugal

ITT Ireland

PUM31164

102706111

SV9206/2F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31165

102706121

SV9206F450T

Vertical Multistage Centrifugal

ITT Ireland

PUM31166

102706131

SV9207/2F450T

Vertical Multistage Centrifugal

ITT Ireland

”.

19. Part 28 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

EVA32232

Verde Scooter 1500w

Verde Scooter 1500w

1500w Electric Scooter

Verde Autos

EVA31520

MB7EVFA1A

REVAi

REVA Electric Car

Reva Electric Car Company

”.

20. Part 30 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

CCU33429

114X4280

OP-MPUC046MLP 00G

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33430

114X4283

OP-MPUC046MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33431

114X4364

OP-MPZC086MTP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33432

114X4310

OP-MPUC068MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33433

114X4323

OP-MPUC080MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33434

114X4343

OP-MPUC107MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33435

114X4488

OP-MPZC171MTP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33436

114X4413

OP-MPUC125MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33437

114X4433

OP-MPUC162MLP 00E

Danfoss Optyma Plus Condensing Unit

Danfoss

CCU33351

120U1016

HRP040T4

Danfoss Scroll Compressor

Danfoss

CCU33352

120U1026

HRP042T4

Danfoss Scroll Compressor

Danfoss

CCU33353

120U1036

HRP045T4

Danfoss Scroll Compressor

Danfoss

CCU33354

120U1046

HRP047T4

Danfoss Scroll Compressor

Danfoss

CCU33355

120U0986

HRP047T5

Danfoss Scroll Compressor

Danfoss

CCU33356

120U1656

HRP048T4

Danfoss Scroll Compressor

Danfoss

CCU33357

120U0596

HRP058T5

Danfoss Scroll Compressor

Danfoss

CCU33358

120U1606

HRP060T5

Danfoss Scroll Compressor

Danfoss

CCU33359

120U1621

HLP068T5

Danfoss Scroll Compressor

Danfoss

CCU33360

120U1756

HLP072T4

Danfoss Scroll Compressor

Danfoss

CCU33361

120U1631

HLP072T5

Danfoss Scroll Compressor

Danfoss

CCU33362

120U1766

HLP075T4

Danfoss Scroll Compressor

Danfoss

CCU33363

120U1641

HLP075T5

Danfoss Scroll Compressor

Danfoss

CCU33364

120U1781

HLP081T4

Danfoss Scroll Compressor

Danfoss

CCU33365

120U1651

HLP081T5

Danfoss Scroll Compressor

Danfoss

CCU33366

120U0601

HCP094T4

Danfoss Scroll Compressor

Danfoss

CCU33367

SZ090-4VI

SZ090-4

Danfoss Scroll Compressor

Danfoss

CCU33368

SZ100-4VI

SZ100-4

Danfoss Scroll Compressor

Danfoss

CCU33369

SZ110-4VI

SZ110-4

Danfoss Scroll Compressor

Danfoss

CCU33370

SZ115-4RI

SZ115-4

Danfoss Scroll Compressor

Danfoss

CCU33371

SZ120-4VI

SZ120-4

Danfoss Scroll Compressor

Danfoss

CCU33372

SZ125-4RI

SZ125-4

Danfoss Scroll Compressor

Danfoss

CCU33373

SZ148-4VAI

SZ148-4

Danfoss Scroll Compressor

Danfoss

CCU33374

SZ160-4RAI

SZ160-4

Danfoss Scroll Compressor

Danfoss

CCU33375

SZ161-4VAI

SZ161-4

Danfoss Scroll Compressor

Danfoss

CCU33376

SZ175-4RI

SZ175-4

Danfoss Scroll Compressor

Danfoss

CCU33377

SZ185-4RI

SZ185-4

Danfoss Scroll Compressor

Danfoss

CCU33378

121U8030

MLZ026T5

Danfoss Scroll Compressor

Danfoss

CCU33379

121U8032

MLZ030T5

Danfoss Scroll Compressor

Danfoss

CCU33380

121U8034

MLZ038T5

Danfoss Scroll Compressor

Danfoss

CCU33381

121U8008

MLZ026T4

Danfoss Scroll Compressor

Danfoss

CCU33382

121U8010

MLZ030T4

Danfoss Scroll Compressor

Danfoss

CCU33383

121U8012

MLZ038T4

Danfoss Scroll Compressor

Danfoss

CCU33384

121U8014

MLZ045T4

Danfoss Scroll Compressor

Danfoss

CCU33385

121U8016

MLZ048T4

Danfoss Scroll Compressor

Danfoss

CCU33386

121U8018

MLZ058T4

Danfoss Scroll Compressor

Danfoss

CCU33387

121U8020

MLZ066T4

Danfoss Scroll Compressor

Danfoss

CCU33388

121U8022

MLZ076T4

Danfoss Scroll Compressor

Danfoss

”.

21. Part 31 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

RDC33400

185(-) AD

Paris 1

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33401

185(-) VSAD

Paris 2

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33402

185(U) VSAD

Paris 3

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33403

210(-) AD

Paris 4

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33404

210(-) VSAD

Paris 5

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33405

210(U) VSAD

Paris 6

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33406

250(-) AD

Paris 7

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33407

250(-) VSAD

Paris 8

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33408

250(U) VSAD

Paris 9

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33409

175(-) AD

Athen XL 1

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33410

175(-) VSAD

Athen XL 2

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33411

210(-) AD

Athen XL 3

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33412

210(-) VSAD

Athen XL 4

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33413

207(-) AD

Athen XL 5

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC33414

207(-) VSAD

Athen XL 6

Plug-In Display Freezer/Sliding Lids

AHT Cooling Systems GmbH

RDC32262

6180006

ARNEG NIMES 2 ES 88/200/250

Narrow width vertical multideck refrigerated display cabinet

Arneg SPA

RDC32263

6180804

ARNEG LISBONA LF 1C 95/216 187 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32264

6180806

ARNEG LISBONA LF 1C 95/216 250 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32265

6180809

ARNEG LISBONA LF 1C 95/216 375 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32266

6180704

ARNEG LISBONA LF 1C 85/216 187 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32267

6180706

ARNEG LISBONA LF 1C 85/216 250 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32268

6180709

ARNEG LISBONA LF 1C 85/216 375 S 230 50

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32269

6180404

ARNEG LISBONA LF 2C 85/200 187 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32270

6180406

ARNEG LISBONA LF 2C 85/200 250 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32271

6180409

ARNEG LISBONA LF 2C 85/200 375 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32272

6208909

ARNEG Panama 750 — 375S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32273

6208904

ARNEG Panama 750 — 187S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32274

6208906

ARNEG Panama 750 — 250S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32275

6180504

ARNEG LISBONA LF 2C 95/200 187 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32276

6180506

ARNEG LISBONA LF 2C 95/200 250 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32277

6180509

ARNEG LISBONA LF 2C 95/200 375 S23050

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32278

6180009

ARNEG NIMES 2 ES 88/200/375

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32279

6180002

ARNEG NIMES 2 ES 88/200/125

Narrow width vertical multideck low front refrigerated display cabinet

Arneg SPA

RDC32949

MJC316-3

Merac Meat Multijet 1.875m

Meat Multideck

Hussmann Koxka S.L.

RDC32950

MJC316-4

Merac Meat Multijet 2.5m

Meat Multideck

Hussmann Koxka S.L.

RDC32951

MJC316-6

Merac Meat Multijet 3.75m

Meat Multideck

Hussmann Koxka S.L.

”.

22. Part 32 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

CON32952

10102014

SAV5R 4510

Axial fan type air cooled condenser

LU-VE SpA

CON32953

10102015

SAV5R 4511

Axial fan type air cooled condenser

LU-VE SpA

CON32954

10102016

SAV5R 4520

Axial fan type air cooled condenser

LU-VE SpA

CON32955

10102017

SAV5R 4521

Axial fan type air cooled condenser

LU-VE SpA

CON32956

10102018

SAV5R 4530

Axial fan type air cooled condenser

LU-VE SpA

CON32957

10101524

SAV5R 4531

Axial fan type air cooled condenser

LU-VE SpA

CON32958

10102019

SAV5R 4545

Axial fan type air cooled condenser

LU-VE SpA

CON32959

10102020

SAV5R 4546

Axial fan type air cooled condenser

LU-VE SpA

CON32960

10101919

SAV5R 4565

Axial fan type air cooled condenser

LU-VE SpA

CON32961

10102021

SAV5R 4566

Axial fan type air cooled condenser

LU-VE SpA

CON32962

10102084

EAV5S 5410

Axial fan type air cooled condenser

LU-VE SpA

CON32963

10102085

EAV5S 5411

Axial fan type air cooled condenser

LU-VE SpA

CON32964

10102091

EAV5S 5420

Axial fan type air cooled condenser

LU-VE SpA

CON32965

10102092

EAV5S 5421

Axial fan type air cooled condenser

LU-VE SpA

CON32966

10102093

EAV5S 5430

Axial fan type air cooled condenser

LU-VE SpA

CON32967

10102094

EAV5S 5431

Axial fan type air cooled condenser

LU-VE SpA

CON32968

10102095

EAV5S 5440

Axial fan type air cooled condenser

LU-VE SpA

CON32969

10102096

EAV5S 5441

Axial fan type air cooled condenser

LU-VE SpA

CON32970

10102100

EAV5S 5450

Axial fan type air cooled condenser

LU-VE SpA

CON32971

10102102

EAV5S 5451

Axial fan type air cooled condenser

LU-VE SpA

CON32972

10102097

EAV5S 5445

Axial fan type air cooled condenser

LU-VE SpA

CON32973

10102099

EAV5S 5446

Axial fan type air cooled condenser

LU-VE SpA

CON32974

10102103

EAV5S 5465

Axial fan type air cooled condenser

LU-VE SpA

CON32975

10102104

EAV5S 5466

Axial fan type air cooled condenser

LU-VE SpA

CON32976

10102105

EAV5S 5485

Axial fan type air cooled condenser

LU-VE SpA

CON32977

10102106

EAV5S 5486

Axial fan type air cooled condenser

LU-VE SpA

CON32978

10102107

EAV5R 5510

Axial fan type air cooled condenser

LU-VE SpA

CON32979

10102108

EAV5R 5511

Axial fan type air cooled condenser

LU-VE SpA

CON32980

10102109

EAV5R 5520

Axial fan type air cooled condenser

LU-VE SpA

CON32981

10102110

EAV5R 5521

Axial fan type air cooled condenser

LU-VE SpA

CON32982

10102111

EAV5R 5530

Axial fan type air cooled condenser

LU-VE SpA

CON32983

10102112

EAV5R 5531

Axial fan type air cooled condenser

LU-VE SpA

CON32984

10102113

EAV5R 5540

Axial fan type air cooled condenser

LU-VE SpA

CON32985

10102115

EAV5R 5541

Axial fan type air cooled condenser

LU-VE SpA

CON32986

10102119

EAV5R 5550

Axial fan type air cooled condenser

LU-VE SpA

CON32987

10102120

EAV5R 5551

Axial fan type air cooled condenser

LU-VE SpA

CON32988

10102116

EAV5R 5545

Axial fan type air cooled condenser

LU-VE SpA

CON32989

10102117

EAV5R 5546

Axial fan type air cooled condenser

LU-VE SpA

CON32990

10102121

EAV5R 5565

Axial fan type air cooled condenser

LU-VE SpA

CON32991

10102122

EAV5R 5566

Axial fan type air cooled condenser

LU-VE SpA

CON32992

10102123

EAV5R 5585

Axial fan type air cooled condenser

LU-VE SpA

CON32993

10102124

EAV5R 5586

Axial fan type air cooled condenser

LU-VE SpA

CON32994

10102156

SAV6S 6511

Axial fan type air cooled condenser

LU-VE SpA

CON32995

10102158

SAV6S 6521

Axial fan type air cooled condenser

LU-VE SpA

CON32996

10102160

SAV6S 6531

Axial fan type air cooled condenser

LU-VE SpA

CON32997

10102162

SAV6S 6541

Axial fan type air cooled condenser

LU-VE SpA

CON32998

10102164

SAV6S 6551

Axial fan type air cooled condenser

LU-VE SpA

CON32999

10102166

SAV6S 6546

Axial fan type air cooled condenser

LU-VE SpA

CON33000

10102163

SAV6S 6566

Axial fan type air cooled condenser

LU-VE SpA

CON33001

10102170

SAV6S 6586

Axial fan type air cooled condenser

LU-VE SpA

CON33002

10102171

SAV6R 6610

Axial fan type air cooled condenser

LU-VE SpA

CON33003

10102172

SAV6R 6611

Axial fan type air cooled condenser

LU-VE SpA

CON33004

10102173

SAV6R 6621

Axial fan type air cooled condenser

LU-VE SpA

CON33005

10102174

SAV6R 6620

Axial fan type air cooled condenser

LU-VE SpA

CON33006

10102176

SAV6R 6630

Axial fan type air cooled condenser

LU-VE SpA

CON33007

10102177

SAV6R 6640

Axial fan type air cooled condenser

LU-VE SpA

CON33008

10102178

SAV6R 6641

Axial fan type air cooled condenser

LU-VE SpA

CON33009

10102181

SAV6R 6650

Axial fan type air cooled condenser

LU-VE SpA

CON33010

10102182

SAV6R 6651

Axial fan type air cooled condenser

LU-VE SpA

CON33011

10102179

SAV6R 6645

Axial fan type air cooled condenser

LU-VE SpA

CON33012

10102180

SAV6R 6646

Axial fan type air cooled condenser

LU-VE SpA

CON33013

10102183

SAV6R 6665

Axial fan type air cooled condenser

LU-VE SpA

CON33014

10102184

SAV6R 6666

Axial fan type air cooled condenser

LU-VE SpA

CON33015

10102185

SAV6R 6685

Axial fan type air cooled condenser

LU-VE SpA

CON33016

10102186

SAV6R 6686

Axial fan type air cooled condenser

LU-VE SpA

CON33017

10102226

EAV6S 7510

Axial fan type air cooled condenser

LU-VE SpA

CON33018

10102228

EAV6S 7511

Axial fan type air cooled condenser

LU-VE SpA

CON33019

10102229

EAV6S 7520

Axial fan type air cooled condenser

LU-VE SpA

CON33020

10102231

EAV6S 7521

Axial fan type air cooled condenser

LU-VE SpA

CON33021

10102232

EAV6S 7530

Axial fan type air cooled condenser

LU-VE SpA

CON33022

10102233

EAV6S 7531

Axial fan type air cooled condenser

LU-VE SpA

CON33023

10102234

EAV6S 7540

Axial fan type air cooled condenser

LU-VE SpA

CON33024

10102235

EAV6S 7541

Axial fan type air cooled condenser

LU-VE SpA

CON33025

10102239

EAV6S 7550

Axial fan type air cooled condenser

LU-VE SpA

CON33026

10102240

EAV6S 7551

Axial fan type air cooled condenser

LU-VE SpA

CON33027

10102236

EAV6S 7545

Axial fan type air cooled condenser

LU-VE SpA

CON33028

10102238

EAV6S 7546

Axial fan type air cooled condenser

LU-VE SpA

CON33029

10102241

EAV6S 7565

Axial fan type air cooled condenser

LU-VE SpA

CON33030

10102242

EAV6S 7566

Axial fan type air cooled condenser

LU-VE SpA

CON33031

10102243

EAV6S 7585

Axial fan type air cooled condenser

LU-VE SpA

CON33032

10102244

EAV6S 7586

Axial fan type air cooled condenser

LU-VE SpA

CON33033

10102246

EAV6R 7610

Axial fan type air cooled condenser

LU-VE SpA

CON33034

10102247

EAV6R 7611

Axial fan type air cooled condenser

LU-VE SpA

CON33035

10102248

EAV6R 7620

Axial fan type air cooled condenser

LU-VE SpA

CON33036

10102249

EAV6R 7621

Axial fan type air cooled condenser

LU-VE SpA

CON33037

10102250

EAV6R 7630

Axial fan type air cooled condenser

LU-VE SpA

CON33038

10102251

EAV6R 7631

Axial fan type air cooled condenser

LU-VE SpA

CON33039

10102252

EAV6R 7640

Axial fan type air cooled condenser

LU-VE SpA

CON33040

10102253

EAV6R 7641

Axial fan type air cooled condenser

LU-VE SpA

CON33041

10102256

EAV6R 7650

Axial fan type air cooled condenser

LU-VE SpA

CON33042

10102258

EAV6R 7651

Axial fan type air cooled condenser

LU-VE SpA

CON33043

10102254

EAV6R 7645

Axial fan type air cooled condenser

LU-VE SpA

CON33044

10102255

EAV6R 7646

Axial fan type air cooled condenser

LU-VE SpA

CON33045

10102259

EAV6R 7665

Axial fan type air cooled condenser

LU-VE SpA

CON33046

10102260

EAV6R 7666

Axial fan type air cooled condenser

LU-VE SpA

CON33047

10102261

EAV6R 7685

Axial fan type air cooled condenser

LU-VE SpA

CON33048

10102263

EAV6R 7686

Axial fan type air cooled condenser

LU-VE SpA

CON33049

10066276

SAV8R 4110

Axial fan type air cooled condenser

LU-VE SpA

CON33050

10066279

SAV8R 4111

Axial fan type air cooled condenser

LU-VE SpA

CON33051

10066283

SAV8R 4120

Axial fan type air cooled condenser

LU-VE SpA

CON33052

10066286

SAV8R 4121

Axial fan type air cooled condenser

LU-VE SpA

CON33053

10066290

SAV8R 4130

Axial fan type air cooled condenser

LU-VE SpA

CON33054

10066293

SAV8R 4131

Axial fan type air cooled condenser

LU-VE SpA

CON33055

10066297

SAV8R 4140

Axial fan type air cooled condenser

LU-VE SpA

CON33056

10066300

SAV8R 4141

Axial fan type air cooled condenser

LU-VE SpA

CON33057

10066304

SAV8R 4150

Axial fan type air cooled condenser

LU-VE SpA

CON33058

10066307

SAV8R 4151

Axial fan type air cooled condenser

LU-VE SpA

CON33059

10066311

SAV8R 4220

Axial fan type air cooled condenser

LU-VE SpA

CON33060

10066314

SAV8R 4221

Axial fan type air cooled condenser

LU-VE SpA

CON33061

10066318

SAV8R 4230

Axial fan type air cooled condenser

LU-VE SpA

CON33062

10066321

SAV8R 4231

Axial fan type air cooled condenser

LU-VE SpA

CON33063

10066325

SAV8R 4240

Axial fan type air cooled condenser

LU-VE SpA

CON33064

10066328

SAV8R 4241

Axial fan type air cooled condenser

LU-VE SpA

CON33065

10066332

SAV8R 4250

Axial fan type air cooled condenser

LU-VE SpA

CON33066

10066335

SAV8R 4251

Axial fan type air cooled condenser

LU-VE SpA

CON33067

10066339

SAV8R 4260

Axial fan type air cooled condenser

LU-VE SpA

CON33068

10066342

SAV8R 4261

Axial fan type air cooled condenser

LU-VE SpA

CON33069

10066346

SAV8R 4270

Axial fan type air cooled condenser

LU-VE SpA

CON33070

10066349

SAV8R 4271

Axial fan type air cooled condenser

LU-VE SpA

CON33071

10066353

SAV8R 4280

Axial fan type air cooled condenser

LU-VE SpA

CON33072

10066356

SAV8R 4281

Axial fan type air cooled condenser

LU-VE SpA

CON33084

10066491

EAV9U 5110

Axial fan type air cooled condenser

LU-VE SpA

CON33085

10066492

EAV9U 5111

Axial fan type air cooled condenser

LU-VE SpA

CON33086

10066493

EAV9U 5120

Axial fan type air cooled condenser

LU-VE SpA

CON33087

10066494

EAV9U 5121

Axial fan type air cooled condenser

LU-VE SpA

CON33088

10066495

EAV9U 5130

Axial fan type air cooled condenser

LU-VE SpA

CON33089

10066496

EAV9U 5131

Axial fan type air cooled condenser

LU-VE SpA

CON33090

10066497

EAV9U 5140

Axial fan type air cooled condenser

LU-VE SpA

CON33091

10066498

EAV9U 5141

Axial fan type air cooled condenser

LU-VE SpA

CON33092

10066499

EAV9U 5150

Axial fan type air cooled condenser

LU-VE SpA

CON33093

10066500

EAV9U 5151

Axial fan type air cooled condenser

LU-VE SpA

CON33094

10066501

EAV9U 5160

Axial fan type air cooled condenser

LU-VE SpA

CON33095

10066502

EAV9U 5161

Axial fan type air cooled condenser

LU-VE SpA

CON33096

10066503

EAV9U 5220

Axial fan type air cooled condenser

LU-VE SpA

CON33097

10066504

EAV9U 5221

Axial fan type air cooled condenser

LU-VE SpA

CON33098

10066505

EAV9U 5230

Axial fan type air cooled condenser

LU-VE SpA

CON33099

10066506

EAV9U 5231

Axial fan type air cooled condenser

LU-VE SpA

CON33100

10066507

EAV9U 5240

Axial fan type air cooled condenser

LU-VE SpA

CON33101

10066508

EAV9U 5241

Axial fan type air cooled condenser

LU-VE SpA

CON33102

10066509

EAV9U 5250

Axial fan type air cooled condenser

LU-VE SpA

CON33103

10066510

EAV9U 5251

Axial fan type air cooled condenser

LU-VE SpA

CON33104

10066511

EAV9U 5260

Axial fan type air cooled condenser

LU-VE SpA

CON33105

10066512

EAV9U 5261

Axial fan type air cooled condenser

LU-VE SpA

CON33106

10066360

EAV8R 9110

Axial fan type air cooled condenser

LU-VE SpA

CON33107

10066364

EAV8R 9111

Axial fan type air cooled condenser

LU-VE SpA

CON33108

10066369

EAV8R 9120

Axial fan type air cooled condenser

LU-VE SpA

CON33109

10066373

EAV8R 9121

Axial fan type air cooled condenser

LU-VE SpA

CON33110

10066378

EAV8R 9130

Axial fan type air cooled condenser

LU-VE SpA

CON33111

10066382

EAV8R 9131

Axial fan type air cooled condenser

LU-VE SpA

CON33112

10066387

EAV8R 9140

Axial fan type air cooled condenser

LU-VE SpA

CON33113

10066391

EAV8R 9141

Axial fan type air cooled condenser

LU-VE SpA

CON33114

10066396

EAV8R 9150

Axial fan type air cooled condenser

LU-VE SpA

CON33115

10066400

EAV8R 9151

Axial fan type air cooled condenser

LU-VE SpA

CON33116

10066405

EAV8R 9160

Axial fan type air cooled condenser

LU-VE SpA

CON33117

10066409

EAV8R 9161

Axial fan type air cooled condenser

LU-VE SpA

CON33118

10066414

EAV8R 9220

Axial fan type air cooled condenser

LU-VE SpA

CON33119

10066418

EAV8R 9221

Axial fan type air cooled condenser

LU-VE SpA

CON33120

10066423

EAV8R 9230

Axial fan type air cooled condenser

LU-VE SpA

CON33121

10066427

EAV8R 9231

Axial fan type air cooled condenser

LU-VE SpA

CON33122

10066432

EAV8R 9240

Axial fan type air cooled condenser

LU-VE SpA

CON33123

10066436

EAV8R 9241

Axial fan type air cooled condenser

LU-VE SpA

CON33124

10066441

EAV8R 9250

Axial fan type air cooled condenser

LU-VE SpA

CON33125

10066445

EAV8R 9251

Axial fan type air cooled condenser

LU-VE SpA

CON33126

10066450

EAV8R 9260

Axial fan type air cooled condenser

LU-VE SpA

CON33127

10066454

EAV8R 9261

Axial fan type air cooled condenser

LU-VE SpA

CON33137

82052073

XDHVT 5114

Axial fan type air cooled condenser

LU-VE SpA

CON33138

82052074

XDHVT 5115

Axial fan type air cooled condenser

LU-VE SpA

CON33140

82052076

XDHVT 5124

Axial fan type air cooled condenser

LU-VE SpA

CON33141

82052077

XDHVT 5125

Axial fan type air cooled condenser

LU-VE SpA

CON33143

82052079

XDHVT 5134

Axial fan type air cooled condenser

LU-VE SpA

CON33144

82052080

XDHVT 5135

Axial fan type air cooled condenser

LU-VE SpA

CON33146

82052082

XDHVT 5144

Axial fan type air cooled condenser

LU-VE SpA

CON33147

82052083

XDHVT 5145

Axial fan type air cooled condenser

LU-VE SpA

CON33149

82052085

XDHVT 5154

Axial fan type air cooled condenser

LU-VE SpA

CON33150

82052086

XDHVT 5155

Axial fan type air cooled condenser

LU-VE SpA

CON33152

82052088

XDHVT 5164

Axial fan type air cooled condenser

LU-VE SpA

CON33153

82052089

XDHVT 5165

Axial fan type air cooled condenser

LU-VE SpA

CON33155

82052091

XDHVT 5174

Axial fan type air cooled condenser

LU-VE SpA

CON33156

82052092

XDHVT 5175

Axial fan type air cooled condenser

LU-VE SpA

CON33157

82052093

XDHVT 5184

Axial fan type air cooled condenser

LU-VE SpA

CON33158

82052094

XDHVT 5185

Axial fan type air cooled condenser

LU-VE SpA

CON33159

82052095

XDHVU 6113

Axial fan type air cooled condenser

LU-VE SpA

CON33160

82052096

XDHVU 6114

Axial fan type air cooled condenser

LU-VE SpA

CON33161

82052097

XDHVU 6123

Axial fan type air cooled condenser

LU-VE SpA

CON33162

82052098

XDHVU 6124

Axial fan type air cooled condenser

LU-VE SpA

CON33163

82052099

XDHVU 6133

Axial fan type air cooled condenser

LU-VE SpA

CON33164

82052100

XDHVU 6134

Axial fan type air cooled condenser

LU-VE SpA

CON33165

82052101

XDHVU 6143

Axial fan type air cooled condenser

LU-VE SpA

CON33166

82052102

XDHVU 6144

Axial fan type air cooled condenser

LU-VE SpA

CON33167

82052103

XDHVU 6153

Axial fan type air cooled condenser

LU-VE SpA

CON33168

82052104

XDHVU 6154

Axial fan type air cooled condenser

LU-VE SpA

CON33169

82052105

XDHVU 6163

Axial fan type air cooled condenser

LU-VE SpA

CON33170

82052106

XDHVU 6164

Axial fan type air cooled condenser

LU-VE SpA

CON33171

82052107

XDHVU 6173

Axial fan type air cooled condenser

LU-VE SpA

CON33172

82052108

XDHVU 6174

Axial fan type air cooled condenser

LU-VE SpA

CON33173

82052109

XDHVU 6183

Axial fan type air cooled condenser

LU-VE SpA

CON33174

82052110

XDHVU 6184

Axial fan type air cooled condenser

LU-VE SpA

CON33175

82052111

XDHVR 7113

Axial fan type air cooled condenser

LU-VE SpA

CON33176

82052112

XDHVR 7114

Axial fan type air cooled condenser

LU-VE SpA

CON33177

82052113

XDHVR 7123

Axial fan type air cooled condenser

LU-VE SpA

CON33178

82052114

XDHVR 7124

Axial fan type air cooled condenser

LU-VE SpA

CON33179

82052115

XDHVR 7133

Axial fan type air cooled condenser

LU-VE SpA

CON33180

82052116

XDHVR 7134

Axial fan type air cooled condenser

LU-VE SpA

CON33181

82052117

XDHVR 7143

Axial fan type air cooled condenser

LU-VE SpA

CON33182

82052118

XDHVR 7144

Axial fan type air cooled condenser

LU-VE SpA

CON33183

82052119

XDHVR 7153

Axial fan type air cooled condenser

LU-VE SpA

CON33184

82052120

XDHVR 7154

Axial fan type air cooled condenser

LU-VE SpA

CON33185

82052121

XDHVR 7163

Axial fan type air cooled condenser

LU-VE SpA

CON33186

82052122

XDHVR 7164

Axial fan type air cooled condenser

LU-VE SpA

CON33187

82052123

XDHVR 7173

Axial fan type air cooled condenser

LU-VE SpA

CON33188

82052124

XDHVR 7174

Axial fan type air cooled condenser

LU-VE SpA

CON33189

82052125

XDHVR 7183

Axial fan type air cooled condenser

LU-VE SpA

CON33190

82052126

XDHVR 7184

Axial fan type air cooled condenser

LU-VE SpA

CON33207

10062275

EHVDT 4226

Axial fan type air cooled condenser

LU-VE SpA

CON33208

10062280

EHVDT 4227

Axial fan type air cooled condenser

LU-VE SpA

CON33209

10062285

EHVDT 4236

Axial fan type air cooled condenser

LU-VE SpA

CON33210

10062290

EHVDT 4237

Axial fan type air cooled condenser

LU-VE SpA

CON33211

10062295

EHVDT 4246

Axial fan type air cooled condenser

LU-VE SpA

CON33212

10062300

EHVDT 4247

Axial fan type air cooled condenser

LU-VE SpA

CON33213

10062305

EHVDT 4256

Axial fan type air cooled condenser

LU-VE SpA

CON33214

10062309

EHVDT 4257

Axial fan type air cooled condenser

LU-VE SpA

CON33215

10062314

EHVDT 4266

Axial fan type air cooled condenser

LU-VE SpA

CON33216

10062319

EHVDT 4267

Axial fan type air cooled condenser

LU-VE SpA

CON33217

10062324

EHVDT 4277

Axial fan type air cooled condenser

LU-VE SpA

CON33218

10062329

EHVDT 4276

Axial fan type air cooled condenser

LU-VE SpA

CON33219

10062334

EHVDT 4286

Axial fan type air cooled condenser

LU-VE SpA

CON33220

10062339

EHVDT 4287

Axial fan type air cooled condenser

LU-VE SpA

CON33221

10062344

EHVDT 4296

Axial fan type air cooled condenser

LU-VE SpA

CON33222

10062349

EHVDT 4297

Axial fan type air cooled condenser

LU-VE SpA

CON33223

10062368

EHVDU 7225

Axial fan type air cooled condenser

LU-VE SpA

CON33224

10062369

EHVDU 7226

Axial fan type air cooled condenser

LU-VE SpA

CON33225

10062370

EHVDU 7235

Axial fan type air cooled condenser

LU-VE SpA

CON33226

10062371

EHVDU 7236

Axial fan type air cooled condenser

LU-VE SpA

CON33227

10062372

EHVDU 7245

Axial fan type air cooled condenser

LU-VE SpA

CON33228

10062373

EHVDU 7246

Axial fan type air cooled condenser

LU-VE SpA

CON33229

10062374

EHVDU 7255

Axial fan type air cooled condenser

LU-VE SpA

CON33230

10062375

EHVDU 7256

Axial fan type air cooled condenser

LU-VE SpA

CON33231

10062376

EHVDU 7265

Axial fan type air cooled condenser

LU-VE SpA

CON33232

10062377

EHVDU 7266

Axial fan type air cooled condenser

LU-VE SpA

CON33233

10062378

EHVDU 7275

Axial fan type air cooled condenser

LU-VE SpA

CON33234

10062379

EHVDU 7276

Axial fan type air cooled condenser

LU-VE SpA

CON33235

10062380

EHVDU 7285

Axial fan type air cooled condenser

LU-VE SpA

CON33236

10062381

EHVDU 7286

Axial fan type air cooled condenser

LU-VE SpA

CON33237

10062382

EHVDU 7295

Axial fan type air cooled condenser

LU-VE SpA

CON33238

10062383

EHVDU 7296

Axial fan type air cooled condenser

LU-VE SpA

CON33239

10062281

EHVDR 5225

Axial fan type air cooled condenser

LU-VE SpA

CON33240

10062276

EHVDR 5226

Axial fan type air cooled condenser

LU-VE SpA

CON33241

10062291

EHVDR 5235

Axial fan type air cooled condenser

LU-VE SpA

CON33242

10062286

EHVDR 5236

Axial fan type air cooled condenser

LU-VE SpA

CON33243

10062301

EHVDR 5245

Axial fan type air cooled condenser

LU-VE SpA

CON33244

10062296

EHVDR 5246

Axial fan type air cooled condenser

LU-VE SpA

CON33245

10062310

EHVDR 5255

Axial fan type air cooled condenser

LU-VE SpA

CON33246

10062351

EHVDR 5256

Axial fan type air cooled condenser

LU-VE SpA

CON33247

10062320

EHVDR 5265

Axial fan type air cooled condenser

LU-VE SpA

CON33248

10062315

EHVDR 5266

Axial fan type air cooled condenser

LU-VE SpA

CON33249

10062330

EHVDR 5275

Axial fan type air cooled condenser

LU-VE SpA

CON33250

10062325

EHVDR 5276

Axial fan type air cooled condenser

LU-VE SpA

CON33251

10062340

EHVDR 5285

Axial fan type air cooled condenser

LU-VE SpA

CON33252

10062335

EHVDR 5286

Axial fan type air cooled condenser

LU-VE SpA

CON33253

10062350

EHVDR 5295

Axial fan type air cooled condenser

LU-VE SpA

CON33254

10062345

EHVDR 5296

Axial fan type air cooled condenser

LU-VE SpA

”.

23. Part 33 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

RSC33288

080Z2521

Danfoss AK-SC255E

System Manager for Control and Monitoring of Refrigeration Systems

Danfoss

RSC33289

080Z2520

Danfoss AK-SC255

System Manager for Control and Monitoring of Refrigeration systems

Danfoss

RSC33290

080Z2583

Danfoss AK-SC255 DIN

System Manager (w/o Display) for Control and Monitoring of Refrigeration Systems

Danfoss

RSC33291

080Z2551

Danfoss AK-CS

System Manager for control and monitoring of regrigeration system and ancilliary equipment in small and medium applications

Danfoss

RSC33347

084B8521

Danfoss EKC202A Controller

Refrigeration Controller for Display cabinets and Cold Rooms

Danfoss

RSC33348

084B8522

Danfoss EKC202B Controller

Refrigeration Display Cabinet and Cold Room Controller

Danfoss

RSC33349

084B8523

Danfoss EKC202C Controller

Refrigeration Display Cabinet and Cold Room Controller

Danfoss

RSC33350

084B8536

Danfoss EKC202D Controller

Refrigeration Display Cabinet and Cold Room Controller

Danfoss

RSC33415

080Z8500

Danfoss AK-SM 350

System Management front End for Refrigeration Applications

Danfoss

RSC33416

080Z8502

Danfoss AK-SM350

System Manager Front End for Refrigeration Applications

Danfoss

RSC33417

080Z8512

Danfoss AK-SM 720

System Management Gateway for Refrigeration Applications

Danfoss

RSC33418

080Z2553

Danfoss AK-CS Din Version

Front End System Manager for Small refrigeration Systems

Danfoss

RSC33419

084B8022

Danfoss AK-CC 450 Screw Terminals

Refrigeration Display Case and Coldroom Controller

Danfoss

RSC33420

084B8023

Danfoss AK-CC 450 Plug and Socket

Refrigeration Display Case and Coldroom Controller

Danfoss

RSC33421

080Z0117

Danfoss AK-PC730

Refrigeration Controller Multiple evaporators and Pack Controller

Danfoss

RSC33422

080Z0112

Danfoss AK-PC840

Refrigeration Controller for Multiple Compressors and Condensers

Danfoss

RSC33424

080Z0141

Danfoss AK-PC740

Refrigeration Controller for Multiple Compressors and Condensers with Oil Management

Danfoss

RSC33425

080Z0151

Danfoss AK-PC780

Refrigeration Controller for Multiple Compressors and Condensers with Oil Control

Danfoss

RSC33440

084B8012

Danfoss AK-PC 520

Refrigeration Controller for Multiple Compressors and Condensers

Danfoss

RSC33389

084B8520

Danfoss AK-CC210 Controller

Refrigeration Display Cabinet and Cold Room Controller

Danfoss

RSC33390

084B8524

Danfoss AK-CC450 Controller

Refrigeration Display Cabinet and Cold Room Controller

Danfoss

RSC33391

084B8011

Danfoss EKC414A1 Controller

Refrigeration Display Case and Cold Room Controller

Danfoss

RSC33392

084B8020

Danfoss AK-CC550 Controller

Refrigeration Display Case and Cold Room Controller

Danfoss

RSC33393

084B7086

Danfoss EKC315A Controller

Refrigeration Controller (Superheat and Temperature) Temperature Input.

Danfoss

RSC33394

084B8030

Danfoss AK-CC550A Controller

Refrigeration Display case and Cold Room Controller optimised for C02 applications

Danfoss

RSC33395

080Z0122

Danfoss AK-CC750 Controller

Refrigeration multi-evaporator controller

Danfoss

RSC33396

080Z0116

Danfoss AK-PC730 Pack Controller

Refrigeration Compressor & Condenser Pack Controller

Danfoss

RSC33397

080Z0111

Danfoss AK-PC840 Pack Controller

Refrigeration Multiple Compressor Pack and Condenser Controller

Danfoss

RSC33398

084B8007

Danfoss AK-PC530 Pack Controller

Refrigeration Compressor Pack and Condenser controller

Danfoss

RSC33399

084B7252

Danfoss EKC326A CO2 Gas Controller

Refrigeration Gas Cooler Controller for CO2 applications

Danfoss

”.

24. Part 35 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

IMM33697

1280130

vc330/60

servo hydrauic

ENGEL UK

IMM33698

2180190

vc750/150

servo hydrauic

ENGEL UK

IMM33699

2340210

vc2050/300

servo hydrauic

ENGEL UK

IMM33700

1280960

e-vic200/65

servo hydraulic / electric injection unit

ENGEL UK

IMM33701

1330975

e-vic310/120

servo hydraulic / electric injection unit

ENGEL UK

IMM33702

4900400

e-vic1640/280

servo hydraulic / electric injection unit

ENGEL UK

IMM33703

4100100

emax80/50

full servo

ENGEL UK

IMM33704

4300200

emotion200/55

full servo

ENGEL UK

IMM33705

4500150

emotion310/100

full servo

ENGEL UK

IMM33706

4900100

emotion740/280

full servo

ENGEL UK

IMM33707

4750300

emotion940/180

full servo

ENGEL UK

IMM33708

4920300

emotion2440/380

full servo

ENGEL UK

IMM33709

4300050

em50/55

full servo

ENGEL UK

IMM33710

4130200

em310/100

full servo

ENGEL UK

IMM33711

4130300

em440/100

full servo

ENGEL UK

IMM33712

4200300

emx740/180

full servo

ENGEL UK

IMM33713

4900300

em1340/280

full servo

ENGEL UK

IMM33714

4020300

em2440/380

full servo

ENGEL UK

”.

25. Part 38 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

VSA32297

ESS-A-1-63

ESS-A-1-63

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32298

ESS-A-1-100

ESS-A-1-100

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32299

ESS-A-1-200

ESS-A-1-200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32300

ESS-A-1-400

ESS-A-1-400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32301

ESS-A-1-600

ESS-A-1-600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32302

ESS-A-1-800

ESS-A-1-800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32303

ESS-A-1-1000

ESS-A-1-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32304

ESS-A-1-1200

ESS-A-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32305

ESS-A-1-1400

ESS-A-1-1400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32306

ESS-A-1-1600

ESS-A-1-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32307

ESS-A-1-1800

ESS-A-1-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32308

ESS-A-1-2000

ESS-A-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32309

ESS-B-1-45

ESS-B-1-45

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32310

ESS-B-1-90

ESS-B-1-90

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32311

ESS-B-1-150

ESS-B-1-150

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32312

ESS-B-1-300

ESS-B-1-300

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32313

ESS-B-1-600

ESS-B-1-600

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32314

ESS-B-1-900

ESS-B-1-900

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32315

ESS-B-1-1200

ESS-B-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32316

ESS-B-1-1500

ESS-B-1-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32317

ESS-B-1-1800

ESS-B-1-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32318

ESS-B-1-2100

ESS-B-1-2100

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32319

ESS-B-1-2400

ESS-B-1-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32320

ESS-B-1-2700

ESS-B-1-2700

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32321

ESS-B-1-3000

ESS-B-1-3000

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32322

ESS-C-1-63

ESS-C-1-63

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32323

ESS-C-1-125

ESS-C-1-125

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32324

ESS-C-1-200

ESS-C-1-200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32325

ESS-C-1-400

ESS-C-1-400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32326

ESS-C-1-800

ESS-C-1-800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32327

ESS-C-1-1200

ESS-C-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32328

ESS-C-1-1600

ESS-C-1-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32329

ESS-C-1-2000

ESS-C-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32330

ESS-C-1-2400

ESS-C-1-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32331

ESS-C-1-2800

ESS-C-1-2800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32332

ESS-C-1-3200

ESS-C-1-3200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32333

ESS-C-1-3600

ESS-C-1-3600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32334

ESS-C-1-4000

ESS-C-1-4000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32335

ESS-D-1-75

ESS-D-1-75

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32336

ESS-D-1-125

ESS-D-1-125

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32337

ESS-D-1-250

ESS-D-1-250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32338

ESS-D-1-500

ESS-D-1-500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32339

ESS-D-1-750

ESS-D-1-750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32340

ESS-D-1-1000

ESS-D-1-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32341

ESS-D-1-1250

ESS-D-1-1250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32342

ESS-D-1-1500

ESS-D-1-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32343

ESS-D-1-1750

ESS-D-1-1750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32344

ESS-D-1-2000

ESS-D-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32345

ESS-D-1-2250

ESS-D-1-2250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32346

ESS-D-1-2500

ESS-D-1-2500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32347

ESS-AV-1-63

ESS-AV-1-63

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32348

ESS-AV-1-100

ESS-AV-1-100

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32349

ESS-AV-1-200

ESS-AV-1-200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32350

ESS-AV-1-400

ESS-AV-1-400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32351

ESS-AV-1-600

ESS-AV-1-600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32352

ESS-AV-1-800

ESS-AV-1-800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32353

ESS-AV-1-1000

ESS-AV-1-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32354

ESS-AV-1-1200

ESS-AV-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32355

ESS-AV-1-1400

ESS-AV-1-1400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32356

ESS-AV-1-1600

ESS-AV-1-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32357

ESS-AV-1-1800

ESS-AV-1-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32358

ESS-AV-1-2000

ESS-AV-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32359

ESS-BV-1-45

ESS-BV-1-45

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32360

ESS-BV-1-90

ESS-BV-1-90

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32361

ESS-BV-1-150

ESS-BV-1-150

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32362

ESS-BV-1-300

ESS-BV-1-300

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32363

ESS-BV-1-600

ESS-BV-1-600

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32364

ESS-BV-1-900

ESS-BV-1-900

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32365

ESS-BV-1-1200

ESS-BV-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32366

ESS-BV-1-1500

ESS-BV-1-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32367

ESS-BV-1-1800

ESS-BV-1-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32368

ESS-BV-1-2100

ESS-BV-1-2100

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32369

ESS-BV-1-2400

ESS-BV-1-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32370

ESS-BV-1-2700

ESS-BV-1-2700

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32371

ESS-BV-1-3000

ESS-BV-1-3000

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32372

ESS-CV-1-63

ESS-CV-1-63

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32373

ESS-CV-1-125

ESS-CV-1-125

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32374

ESS-CV-1-200

ESS-CV-1-200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32375

ESS-CV-1-400

ESS-CV-1-400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32376

ESS-CV-1-800

ESS-CV-1-800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32377

ESS-CV-1-1200

ESS-CV-1-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32378

ESS-CV-1-1600

ESS-CV-1-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32379

ESS-CV-1-2000

ESS-CV-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32380

ESS-CV-1-2400

ESS-CV-1-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32381

ESS-CV-1-2800

ESS-CV-1-2800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32382

ESS-CV-1-3200

ESS-CV-1-3200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32383

ESS-CV-1-3600

ESS-CV-1-3600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32384

ESS-CV-1-4000

ESS-CV-1-4000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32385

ESS-DV-1-75

ESS-DV-1-75

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32386

ESS-DV-1-125

ESS-DV-1-125

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32387

ESS-DV-1-250

ESS-DV-1-250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32388

ESS-DV-1-500

ESS-DV-1-500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32389

ESS-DV-1-750

ESS-DV-1-750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32390

ESS-DV-1-1000

ESS-DV-1-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32391

ESS-DV-1-1250

ESS-DV-1-1250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32392

ESS-DV-1-1500

ESS-DV-1-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32393

ESS-DV-1-1750

ESS-DV-1-1750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32394

ESS-DV-1-2000

ESS-DV-1-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32395

ESS-DV-1-2250

ESS-DV-1-2250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32396

ESS-DV-1-2500

ESS-DV-1-2500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32397

ESS-A-3-32

ESS-A-3-32

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32398

ESS-A-3-63

ESS-A-3-63

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32399

ESS-A-3-100

ESS-A-3-100

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32400

ESS-A-3-200

ESS-A-3-200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32401

ESS-A-3-400

ESS-A-3-400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32402

ESS-A-3-600

ESS-A-3-600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32403

ESS-A-3-800

ESS-A-3-800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32404

ESS-A-3-1000

ESS-A-3-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32405

ESS-A-3-1200

ESS-A-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32406

ESS-A-3-1400

ESS-A-3-1400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32407

ESS-A-3-1600

ESS-A-3-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32408

ESS-A-3-1800

ESS-A-3-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32409

ESS-A-3-2000

ESS-A-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’

Claude Lyons Limited

VSA32410

ESS-B-3-45

ESS-B-3-45

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32411

ESS-B-3-90

ESS-B-3-90

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32412

ESS-B-3-150

ESS-B-3-150

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32413

ESS-B-3-300

ESS-B-3-300

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32414

ESS-B-3-600

ESS-B-3-600

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32415

ESS-B-3-900

ESS-B-3-900

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32416

ESS-B-3-1200

ESS-B-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32417

ESS-B-3-1500

ESS-B-3-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32418

ESS-B-3-1800

ESS-B-3-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32419

ESS-B-3-2100

ESS-B-3-2100

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32420

ESS-B-3-2400

ESS-B-3-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32421

ESS-B-3-2700

ESS-B-3-2700

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’

Claude Lyons Limited

VSA32422

ESS-C-3-63

ESS-C-3-63

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32423

ESS-C-3-125

ESS-C-3-125

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32424

ESS-C-3-200

ESS-C-3-200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32425

ESS-C-3-400

ESS-C-3-400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32426

ESS-C-3-800

ESS-C-3-800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32427

ESS-C-3-1200

ESS-C-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32428

ESS-C-3-1600

ESS-C-3-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32429

ESS-C-3-2000

ESS-C-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32430

ESS-C-3-2400

ESS-C-3-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’

Claude Lyons Limited

VSA32431

ESS-D-3-40

ESS-D-3-40

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32432

ESS-D-3-75

ESS-D-3-75

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32433

ESS-D-3-125

ESS-D-3-125

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32434

ESS-D-3-250

ESS-D-3-250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32435

ESS-D-3-500

ESS-D-3-500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32436

ESS-D-3-750

ESS-D-3-750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32437

ESS-D-3-1000

ESS-D-3-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32438

ESS-D-3-1250

ESS-D-3-1250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32439

ESS-D-3-1500

ESS-D-3-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32440

ESS-D-3-1750

ESS-D-3-1750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32441

ESS-D-3-2000

ESS-D-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32442

ESS-D-3-2250

ESS-D-3-2250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32443

ESS-D-3-2500

ESS-D-3-2500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’

Claude Lyons Limited

VSA32444

ESS-AV-3-32

ESS-AV-3-32

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32445

ESS-AV-3-63

ESS-AV-3-63

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32446

ESS-AV-3-100

ESS-AV-3-100

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32447

ESS-AV-3-200

ESS-AV-3-200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32448

ESS-AV-3-400

ESS-AV-3-400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32449

ESS-AV-3-600

ESS-AV-3-600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32450

ESS-AV-3-800

ESS-AV-3-800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32451

ESS-AV-3-1000

ESS-AV-3-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32452

ESS-AV-3-1200

ESS-AV-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32453

ESS-AV-3-1400

ESS-AV-3-1400

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32454

ESS-AV-3-1600

ESS-AV-3-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32455

ESS-AV-3-1800

ESS-AV-3-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32456

ESS-AV-3-2000

ESS-AV-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with 264V input voltage option

Claude Lyons Limited

VSA32457

ESS-BV-3-45

ESS-BV-3-45

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32458

ESS-BV-3-90

ESS-BV-3-90

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32459

ESS-BV-3-150

ESS-BV-3-150

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32460

ESS-BV-3-300

ESS-BV-3-300

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32461

ESS-BV-3-600

ESS-BV-3-600

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32462

ESS-BV-3-900

ESS-BV-3-900

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32463

ESS-BV-3-1200

ESS-BV-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32464

ESS-BV-3-1500

ESS-BV-3-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32465

ESS-BV-3-1800

ESS-BV-3-1800

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32466

ESS-BV-3-2100

ESS-BV-3-2100

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32467

ESS-BV-3-2400

ESS-BV-3-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32468

ESS-BV-3-2700

ESS-BV-3-2700

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with 264V input voltage option

Claude Lyons Limited

VSA32469

ESS-CV-3-63

ESS-CV-3-63

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32470

ESS-CV-3-125

ESS-CV-3-125

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32471

ESS-CV-3-200

ESS-CV-3-200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32472

ESS-CV-3-400

ESS-CV-3-400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32473

ESS-CV-3-800

ESS-CV-3-800

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32474

ESS-CV-3-1200

ESS-CV-3-1200

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32475

ESS-CV-3-1600

ESS-CV-3-1600

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32476

ESS-CV-3-2000

ESS-CV-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32477

ESS-CV-3-2400

ESS-CV-3-2400

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with 264V input voltage option

Claude Lyons Limited

VSA32478

ESS-DV-3-40

ESS-DV-3-40

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32479

ESS-DV-3-75

ESS-DV-3-75

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32480

ESS-DV-3-125

ESS-DV-3-125

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32481

ESS-DV-3-250

ESS-DV-3-250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32482

ESS-DV-3-500

ESS-DV-3-500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32483

ESS-DV-3-750

ESS-DV-3-750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32484

ESS-DV-3-1000

ESS-DV-3-1000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32485

ESS-DV-3-1250

ESS-DV-3-1250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32486

ESS-DV-3-1500

ESS-DV-3-1500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32487

ESS-DV-3-1750

ESS-DV-3-1750

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32488

ESS-DV-3-2000

ESS-DV-3-2000

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32489

ESS-DV-3-2250

ESS-DV-3-2250

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32490

ESS-DV-3-2500

ESS-DV-3-2500

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with 264V input voltage option

Claude Lyons Limited

VSA32491

ESS-A-1-63 ‘S’

ESS-A-1-63 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32492

ESS-A-1-100 ‘S’

ESS-A-1-100 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32493

ESS-A-1-200 ‘S’

ESS-A-1-200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32494

ESS-A-1-400 ‘S’

ESS-A-1-400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32495

ESS-A-1-600 ‘S’

ESS-A-1-600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32496

ESS-A-1-800 ‘S’

ESS-A-1-800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32497

ESS-A-1-1000 ‘S’

ESS-A-1-1000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32498

ESS-A-1-1200 ‘S’

ESS-A-1-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32499

ESS-A-1-1400 ‘S’

ESS-A-1-1400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32500

ESS-A-1-1600 ‘S’

ESS-A-1-1600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32501

ESS-A-1-1800 ‘S’

ESS-A-1-1800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32502

ESS-A-1-2000 ‘S’

ESS-A-1-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32503

ESS-B-1-45 ‘S’

ESS-B-1-45 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32504

ESS-B-1-90 ‘S’

ESS-B-1-90 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32505

ESS-B-1-150 ‘S’

ESS-B-1-150 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32506

ESS-B-1-300 ‘S’

ESS-B-1-300 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32507

ESS-B-1-600 ‘S’

ESS-B-1-600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32508

ESS-B-1-900 ‘S’

ESS-B-1-900 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32509

ESS-B-1-1200 ‘S’

ESS-B-1-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32510

ESS-B-1-1500 ‘S’

ESS-B-1-1500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32511

ESS-B-1-1800 ‘S’

ESS-B-1-1800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32512

ESS-B-1-2100 ‘S’

ESS-B-1-2100 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32513

ESS-B-1-2400 ‘S’

ESS-B-1-2400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32514

ESS-B-1-2700 ‘S’

ESS-B-1-2700 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32515

ESS-B-1-3000 ‘S’

ESS-B-1-3000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32516

ESS-C-1-63 ‘S’

ESS-C-1-63 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32517

ESS-C-1-125 ‘S’

ESS-C-1-125 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32518

ESS-C-1-200 ‘S’

ESS-C-1-200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32519

ESS-C-1-400 ‘S’

ESS-C-1-400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32520

ESS-C-1-800 ‘S’

ESS-C-1-800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32521

ESS-C-1-1200 ‘S’

ESS-C-1-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32522

ESS-C-1-1600 ‘S’

ESS-C-1-1600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32523

ESS-C-1-2000 ‘S’

ESS-C-1-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32524

ESS-C-1-2400 ‘S’

ESS-C-1-2400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32525

ESS-C-1-2800 ‘S’

ESS-C-1-2800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32526

ESS-C-1-3200 ‘S’

ESS-C-1-3200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32527

ESS-C-1-3600 ‘S’

ESS-C-1-3600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32528

ESS-C-1-4000 ‘S’

ESS-C-1-4000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32529

ESS-D-1-75 ‘S’

ESS-D-1-75 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32530

ESS-D-1-125 ‘S’

ESS-D-1-125 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32531

ESS-D-1-250 ‘S’

ESS-D-1-250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32532

ESS-D-1-500 ‘S’

ESS-D-1-500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32533

ESS-D-1-750 ‘S’

ESS-D-1-750 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32534

ESS-D-1-1000 ‘S’

ESS-D-1-1000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32535

ESS-D-1-1250 ‘S’

ESS-D-1-1250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32536

ESS-D-1-1500 ‘S’

ESS-D-1-1500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32537

ESS-D-1-1750 ‘S’

ESS-D-1-1750 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32538

ESS-D-1-2000 ‘S’

ESS-D-1-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32539

ESS-D-1-2250 ‘S’

ESS-D-1-2250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32540

ESS-D-1-2500 ‘S’

ESS-D-1-2500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32541

ESS-A-3-32 ‘S’

ESS-A-3-32 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32542

ESS-A-3-63 ‘S’

ESS-A-3-63 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32543

ESS-A-3-100 ‘S’

ESS-A-3-100 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32544

ESS-A-3-200 ‘S’

ESS-A-3-200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32545

ESS-A-3-400 ‘S’

ESS-A-3-400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32546

ESS-A-3-600 ‘S’

ESS-A-3-600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32547

ESS-A-3-800 ‘S’

ESS-A-3-800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32548

ESS-A-3-1000 ‘S’

ESS-A-3-1000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32549

ESS-A-3-1200 ‘S’

ESS-A-3-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32550

ESS-A-3-1400 ‘S’

ESS-A-3-1400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32551

ESS-A-3-1600 ‘S’

ESS-A-3-1600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32552

ESS-A-3-1800 ‘S’

ESS-A-3-1800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32553

ESS-A-3-2000 ‘S’

ESS-A-3-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —12.5%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32554

ESS-B-3-45 ‘S’

ESS-B-3-45 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32555

ESS-B-3-90 ‘S’

ESS-B-3-90 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32556

ESS-B-3-150 ‘S’

ESS-B-3-150 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32557

ESS-B-3-300 ‘S’

ESS-B-3-300 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32558

ESS-B-3-600 ‘S’

ESS-B-3-600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32559

ESS-B-3-900 ‘S’

ESS-B-3-900 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32560

ESS-B-3-1200 ‘S’

ESS-B-3-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32561

ESS-B-3-1500 ‘S’

ESS-B-3-1500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32562

ESS-B-3-1800 ‘S’

ESS-B-3-1800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32563

ESS-B-3-2100 ‘S’

ESS-B-3-2100 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32564

ESS-B-3-2400 ‘S’

ESS-B-3-2400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32565

ESS-B-3-2700 ‘S’

ESS-B-3-2700 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —8.33%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32566

ESS-C-3-63 ‘S’

ESS-C-3-63 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32567

ESS-C-3-125 ‘S’

ESS-C-3-125 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32568

ESS-C-3-200 ‘S’

ESS-C-3-200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32569

ESS-C-3-400 ‘S’

ESS-C-3-400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32570

ESS-C-3-800 ‘S’

ESS-C-3-800 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32571

ESS-C-3-1200 ‘S’

ESS-C-3-1200 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32572

ESS-C-3-1600 ‘S’

ESS-C-3-1600 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32573

ESS-C-3-2000 ‘S’

ESS-C-3-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32574

ESS-C-3-2400 ‘S’

ESS-C-3-2400 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —6.25%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32575

ESS-D-3-40 ‘S’

ESS-D-3-40 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32576

ESS-D-3-75 ‘S’

ESS-D-3-75 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32577

ESS-D-3-125 ‘S’

ESS-D-3-125 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32578

ESS-D-3-250 ‘S’

ESS-D-3-250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32579

ESS-D-3-500 ‘S’

ESS-D-3-500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32580

ESS-D-3-750 ‘S’

ESS-D-3-750 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32581

ESS-D-3-1000 ‘S’

ESS-D-3-1000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32582

ESS-D-3-1250 ‘S’

ESS-D-3-1250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32583

ESS-D-3-1500 ‘S’

ESS-D-3-1500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32584

ESS-D-3-1750 ‘S’

ESS-D-3-1750 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32585

ESS-D-3-2000 ‘S’

ESS-D-3-2000 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32586

ESS-D-3-2250 ‘S’

ESS-D-3-2250 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32587

ESS-D-3-2500 ‘S’

ESS-D-3-2500 ‘S’

Dynamic voltage optimisation, voltage correction range ‘0 to —10%’ with remote monitoring and metering options

Claude Lyons Limited

VSA32588

TS-3.5

TS-3.5

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32589

TS-4

TS-4

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32590

TS-5

TS-5

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32591

TS-6

TS-6

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32592

TS-8

TS-8

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32593

TS-9

TS-9

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32594

TS-10

TS-10

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32595

TS-11

TS-11

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32596

TS-12

TS-12

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32597

TS-2.5/3

TS-2.5/3

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32598

TS-333

TS-333

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32599

TS-3.5/3

TS-3.5/3

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32600

TS-444

TS-444

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32601

TS-555

TS-555

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32602

TS-666

TS-666

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32603

TS-777

TS-777

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32604

TS-888

TS-888

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32605

TS-999

TS-999

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32606

TS-1010

TS-1010

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32607

TS-1111

TS-1111

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32608

TS-1212

TS-1212

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —17.5 +7.5%, Tap B — / +12.5%, Tap C —7.5 +17.5%

Claude Lyons Limited

VSA32609

TS-4X

TS-4X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32610

TS-5X

TS-5X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32611

TS-6X

TS-6X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32612

TS-8X

TS-8X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32613

TS-9X

TS-9X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32614

TS-10X

TS-10X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32615

TS-11X

TS-11X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32616

TS-12X

TS-12X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32617

TS-333 X

TS-333 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32618

TS-3.5/3 X

TS-3.5/3 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32619

TS-444 X

TS-444 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32620

TS-555 X

TS-555 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32621

TS-666 X

TS-666 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32622

TS-777 X

TS-777 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32623

TS-888 X

TS-888 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32624

TS-999 X

TS-999 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32625

TS-1010 X

TS-1010 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32626

TS-1111 X

TS-1111 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

VSA32627

TS-1212 X

TS-1212 X

Servo mechanical AC voltage regulators/ stabilisers, Voltage correction ranges; Tap A —21 +9%, Tap B — / +15%, Tap C —9 +21%

Claude Lyons Limited

”.

26. Part 47 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

IOS33441

VS4-ENT-C

VMware vSphere 4 Enterprise for 1 processor (Max 6 cores per processor)

VMware vSphere 4 Enterprise for 1 processor (Max 6 cores per processor)

VMware International Limited

IOS33442

VS4-ENT-PL-C

VMware vSphere 4 Enterprise Plus for 1 processor (Max 12 cores per processor)

VMware vSphere 4 Enterprise Plus for 1 processor (Max 12 cores per processor)

VMware International Limited

IOS33443

VS4-EP-AK-VU-PRO

VMware vSphere Enterprise Plus Acceleration Kit PROMO for 8 processors

VMware vSphere Enterprise Plus Acceleration Kit PROMO for 8 processors

VMware International Limited

IOS33444

VS4-MS-AK-VU-PRO

VMware vSphere Midsize Acceleration Kit PROMO for 6 processors

VMware vSphere Midsize Acceleration Kit PROMO for 6 processors

VMware International Limited

IOS33445

VCS-FND-C

VMware vCenter Server 4 Foundation for vSphere up to 3 hosts

VMware vCenter Server 4 Foundation for vSphere up to 3 hosts

VMware International Limited

IOS33446

VCS-STD-C

VMware vCenter Server 4 Standard for vSphere (Includes Orchestrator and Linked Mode)

VMware vCenter Server 4 Standard for vSphere (Includes Orchestrator and Linked Mode)

VMware International Limited

IOS33447

VU4-PR-10-C

VMware View 4 Premier Bundle: 10 Pack

VMware View 4 Premier Bundle: 10 Pack

VMware International Limited

IOS33448

VU4-PR-100-C

VMware View 4 Premier Bundle: 100 Pack

VMware View 4 Premier Bundle: 100 Pack

VMware International Limited

”.

27. Part 49 of Schedule 2 of the Principal Order is amended by inserting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

BBO32285

USV 50 Wood Chips

KWB Multifire USV50_ W

The KWB Multifire system runs on G30/W30 wood chips in accordance with ONORM M 7133 or B1 in accordance with CEN TC 335.

KWB Biomass Heating Systems

BBO32286

USV 50 Wood Pellets

KWB Multifire USV50_ P

The KWB Multifire system runs on wood pellets dia=6 mm / dia=8 mm in accordance with ONORM M 7135 or DIN Plus and industrial pellets dia=11 mm in accordance with ONORM M 7135 HP2.

KWB Biomass Heating Systems

BBO32287

USV 60 Wood Chips

KWB Multifire USV60_ W

The KWB Multifire system runs on G30/W30 wood chips in accordance with ONORM M 7133 or B1 in accordance with CEN TC 335.

KWB Biomass Heating Systems

BBO32288

USV 60 Wood Pellets

KWB Multifire USV60_ P

The KWB Multifire system runs on wood pellets dia=6 mm / dia=8 mm in accordance with ONORM M 7135 or DIN Plus and industrial pellets dia=11 mm in accordance with ONORM M 7135 HP2.

KWB Biomass Heating Systems

BBO32289

USV 80 Wood Chips

KWB Multifire USV80_ W

The KWB Multifire system runs on G30/W30 wood chips in accordance with ONORM M 7133 or B1 in accordance with CEN TC 335.

KWB Biomass Heating Systems

BBO32290

USV 80 Wood Pellets

KWB Multifire USV80_ P

The KWB Multifire system runs on wood pellets dia=6 mm / dia=8 mm in accordance with ONORM M 7135 or DIN Plus and industrial pellets dia=11 mm in accordance with ONORM M 7135 HP2.

KWB Biomass Heating Systems

BBO32291

USV 100 Wood Chips

KWB Multifire USV100_ W

The KWB Multifire system runs on G30/W30 wood chips in accordance with ONORM M 7133 or B1 in accordance with CEN TC 335.

KWB Biomass Heating Systems

BBO32292

USV 100 Wood Pellets

KWB Multifire USV100_ P

The KWB Multifire system runs on wood pellets dia=6 mm / dia=8 mm in accordance with ONORM M 7135 or DIN Plus and industrial pellets dia=11 mm in accordance with ONORM M 7135 HP2.

KWB Biomass Heating Systems

BBO32293

TDS 130 Multifuel

KWB Powerfire TDS130

The KWB Powerfire operates on wood chips (G30/G50 in accordance with ONORM M7133) with up to 45 % water content, as well as wood pellets/ industrial pellets (dia=11mm) in accordance with ONORM M7135 or DIN Plus.

KWB Biomass Heating Systems

BBO32294

TDS 150 Multifuel

KWB Powerfire TDS150

The KWB Powerfire operates on wood chips (G30/G50 in accordance with ONORM M7133) with up to 45 % water content, as well as wood pellets/ industrial pellets (dia=11mm) in accordance with ONORM M7135 or DIN Plus.

KWB Biomass Heating Systems

BBO32295

TDS 240 Multifuel

KWB Powerfire TDS240

The KWB Powerfire operates on wood chips (G30/G50 in accordance with ONORM M7133) with up to 45 % water content, as well as wood pellets/ industrial pellets (dia=11mm) in accordance with ONORM M7135 or DIN Plus.

KWB Biomass Heating Systems

BBO32296

TDS 300 Multifuel

KWB Powerfire TDS300

The KWB Powerfire operates on wood chips (G30/G50 in accordance with ONORM M7133) with up to 45 % water content, as well as wood pellets/ industrial pellets (dia=11mm) in accordance with ONORM M7135 or DIN Plus.

KWB Biomass Heating Systems

”.

28. Part 3 of Schedule 2 of the Principal Order is amended by deleting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

LIG9367

T5-ZP-28

T8/T5 Adapter 28W w Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9366

T5-ZH-28

T8/T5 Adapter 28W w/o Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9365

T5-ZP-21

T8/T5 Adapter 21W

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9364

T5-ZH-21

T8/T5 Adapter 21W w/o Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9363

T5-ZP-14

T8/T5 Adapter 14W w Refelctor

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9362

T5-ZH-14

T8/T5 Adapter 14W w/o Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9369

T5-XP-35

T8/T5 Adapter 35W w Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

LIG9368

T5-X1-35

T8/T5 Adapter 35W w/o Reflector

Luminaire adaptor converting units with electromagnetic ballasts from T8/T12 fluorescent tubes (by use of electronic conversion units) to T5 fluorescent tubes.

Scremir

”.

29. Part 4 of Schedule 2 of the Principal Order is amended by deleting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

LCO30306

DIN-INT-CI-08

eDIN input/output module

An eight channel adaptable input/output which can be configured to accept 0-10v, DSI or switched contact as inputs or provide 0-10v, DSI or DMX outputs

Mode Lighting Ltd.

”.

30. Part 6 of Schedule 2 of the Principal Order is amended by deleting the following:

Triple E Code

Product Code

Product Name

Short Description

Manufacturer

ESE31538

R910 X7560

PowerEdge R910 X7560

4S, 4U Rack, 64 DIMMS, 16 HDDs, 10 PCI, 4 LOMS (2 x 10GB), Intel X7560 processor

Dell

”.

The Minister for Finance approves the making of the foregoing Order.

/images/ls

GIVEN under my Official Seal

18 October 2010

BRIAN LENIHAN,

Minister for Finance.

/images/ls

GIVEN under my Official Seal,

20 October 2010.

EAMON RYAN,

Minister for Communications, Energy and Natural Resources.

EXPLANATORY NOTE

(This note is not part of the Instrument and does not purport to be a legal interpretation)

The effect of this Order is to update, in accordance with the provisions of section 285A of the Taxes Consolidation Act 1997 (inserted by section 46 of the Finance Act 2008 ), those energy efficient products whose capital cost will be eligible for accelerated capital allowances and to update the energy efficiency criteria used to determine eligibility for inclusion on those product lists.

The Accelerated Capital Allowance Scheme will involve quarterly updates to those product lists.

1Initial lumens measured after 100 hours operation.

2 Some fluorescent lamps are labelled and branded with the wattage (power) consumed when operated on standard 50Hz (i.e. not high-frequency) control gear. When operated on high-frequency control gear the watts consumed are less.

3Hydrofluorocarbon

4Hydrocarbon

5Pan size as per Gastronorm

6S.I. No. 341/2005 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 376/2008 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment)(Amendment) Regulations 2008.

7S.I. No. 340/2005 — Waste Management (Waste Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 375/2008 — Waste Management (Waste Electrical and Electronic Equipment) (Amendment) Regulations 2008.

8S.I. No. 341/2005 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 376/2008 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment)(Amendment) Regulations 2008.

9S.I. No. 340/2005 — Waste Management (Waste Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 375/2008 — Waste Management (Waste Electrical and Electronic Equipment) (Amendment) Regulations 2008.

10S.I. No. 341/2005 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 376/2008 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment)(Amendment) Regulations 2008.

11S.I. No. 340/2005 — Waste Management (Waste Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 375/2008 — Waste Management (Waste Electrical and Electronic Equipment) (Amendment) Regulations 2008.

12S.I. No. 341/2005 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 376/2008 — Waste Management (Restriction of Certain Hazardous Substances in Electrical and Electronic Equipment)(Amendment) Regulations 2008.

13S.I. No. 340/2005 — Waste Management (Waste Electrical and Electronic Equipment) Regulations 2005 as amended by S.I. No. 375/2008 — Waste Management (Waste Electrical and Electronic Equipment) (Amendment) Regulations 2008.

14Physical to Virtual is often termed P2V.

15The 80 PLUS performance specification requires multi-output power supplies in computers and servers to be 80% or greater energy-efficient at 20%, 50% and 100% of rated load with a true power factor of 0.9 or greater.

16The Energy Star compliance certification for external power supply is issued by the United Stated Environmental Protection Agency (EPA) in recognition of a product’s compliance with defined efficiency levels as set out in the relevant EPA specification for external power supplies.

17As per ECR Specification V2.1.1